Background: Infrared ear thermometry is widely used in clinical practice due to its noninvasive, convenient, and quick sampling. However, its accuracy and feasibility in anesthetized patients have not yet been established.
Methods: We conducted this cross-sectional study to evaluate the agreement between infrared ear temperature and nasopharyngeal temperature in general anesthetized patients and its performance in intraoperative hypothermia, defined as nasopharyngeal temperature <36°C. Adult female patients who underwent gynecological surgery under general anesthesia were enrolled in this study. Infrared ear temperature by Braun ThermoScan PRO 4000 (Braun GmbH, Kronberg, Germany) and nasopharyngeal temperature were measured simultaneously before, during, and after surgery. The agreement between the two temperatures was assessed using the intraclass correlation coefficient (ICC) and Bland-Altman analysis. The diagnostic performance of the infrared ear thermometer for hypothermia was evaluated using receiver operating characteristic (ROC) curve analysis.
Results: Fifty-six patients with 168 pairs of simultaneous infrared ear and nasopharyngeal temperatures were included in this analysis. The mean infrared ear temperature was consistently higher than the nasopharyngeal temperature throughout surgery, but the differences were small (0.22, 0.13, and 0.06°C before, during, and after surgery, respectively). The ICC between the two temperatures before, during, and after surgery was 0.70, 0.75, and 0.80, respectively, and 93.5% of the differences fell within the 95% limits of agreement of ±0.5°C. An infrared ear thermometer had high diagnostic accuracy for hypothermia, with an area under the ROC curve of 0.95 (95% confidence interval [CI], 0.92-0.98). The cutoff of infrared ear temperature for hypothermia was 36.2°C with a sensitivity of 0.89 (95% CI, 0.71-0.98) and a specificity of 0.87 (95% CI, 0.81-0.92).
Conclusion: The infrared ear temperature is in good agreement with the nasopharyngeal temperature in general anesthetized patients without hyperthermia and has high performance for detecting hypothermia. An infrared ear thermometer can be a diagnostic tool for intraoperative hypothermia.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/JCMA.0000000000000770 | DOI Listing |
Trends Hear
January 2025
Bionics Institute, East Melbourne, VIC, Australia.
This study used functional near-infrared spectroscopy (fNIRS) to measure aspects of the speech discrimination ability of sleeping infants. We examined the morphology of the fNIRS response to three different speech contrasts, namely "Tea/Ba," "Bee/Ba," and "Ga/Ba." Sixteen infants aged between 3 and 13 months old were included in this study and their fNIRS data were recorded during natural sleep.
View Article and Find Full Text PDFFront Cell Dev Biol
January 2025
Fujian Provincial Hospital, Shengli Clinical Medical College of Fujian Medical University, Fuzhou University Affiliated Provincial Hospital, Fuzhou, China.
Purpose: To investigate the changes in meibomian gland (MG) structure in allergic conjunctivitis (AC) patients using an intelligent quantitative analysis algorithm and to explore the relationship between these changes and clinical parameters.
Methods: A total of 252 eyes from patients with AC and 200 eyes from normal controls were examined. Infrared meibography was performed using the non-contact mode of the Keratograph 5M.
Adv Sci (Weinh)
January 2025
Department of Otolaryngology Head and Neck Surgery, Nanjing Drum Tower Hospital, Jiangsu Provincial Key Medical Discipline, Nanjing University Medical School, Nanjing, 210008, China.
Cisplatin-induced ototoxicity is attributed to the aberrant accumulation of reactive oxygen species (ROS) within the inner ear. Antioxidants represented by α-lipoic acid (ALA) have been demonstrated to scavenge ROS in the cochlea, while effective delivery of these agents in vivo remains a major challenge. Here, a novel polydopamine (PDA) nanogel decorated adhesive and responsive hierarchical microcarriers for controllable is presented ALA delivery and deafness prevention.
View Article and Find Full Text PDFAnimals (Basel)
December 2024
Information Technology Research Center, Beijing Academy of Agriculture and Forestry Sciences, Beijing 100097, China.
The stable physiological structure and rich vascular network of pig ears contribute to distinct thermal characteristics, which can reflect temperature variations. While the temperature of the pig ear does not directly represent core body temperature due to the ear's role in thermoregulation, thermal infrared imaging offers a feasible approach to analyzing individual pig status. Based on this background, a dataset comprising 23,189 thermal infrared images of pig ears (TIRPigEar) was established.
View Article and Find Full Text PDFInt Ophthalmol
December 2024
Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital, 32 Gisborne St, East Melbourne, Australia.
Objective: Near-infrared reflectance (NIR) is a commonly performed noncontact and rapid imaging technique. This paper reviews the clinical applications of NIR for diagnosing and monitoring retinal diseases.
Methods: A comprehensive search was conducted across the Pubmed database.