Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The influence of hemolysis was evaluated for 26 clinical chemistry parameters on DxC 700AU (Beckman Coulter®). Ten sample pools were prepared and separated into six aliquots. These aliquots were overloaded with hemolysis in increasing amounts to reach levels equivalent to the maximum hemolysis thresholds H1 (+), H2 (++), H3 (+++) and H4 (++++). Each aliquot is compared to its reference aliquot (not hemolyzed) and a ratio is calculated for each parameter. We proposed that there was a significant difference if, for a given analyte and threshold, more than 20% of the ratios are above the total acceptable limit variability. A significant difference was found for TGP, TGO, cholesterol, creatine kinase (CPK), lactate deshydrogenase (LDH), phosphorus and potassium at H1 (+), chlorine, iron, γ-glutamyltransferase (GGT), and magnesium at H2 (++), amylase and alkaline phosphatase (PAL) at H3 (++++), and prealbumin at H4 (++++). No interference was found until H4 included for uric acid, calcium, creatinine, lipase, glucose, HDL-cholesterol, triglycerides, urea, sodium and immunoglobulins A, G and M. The overestimation of kalemia was calculated as a function of hemolysis, ranging from 0.28 mM +/–0.047 (upper H1 threshold) to 1.37 mM +/–0.126 (upper H4 threshold). Its estimation makes it possible to propose a result rendering algorithm of kalemia according to the hemolysis index. Evaluation of the automates hemolysis indexes is highly recommended for each laboratory. It can allow for some critical parameters the establishment of a decision tree facilitating the result rendering, after clinicobiological consultation.