Objective: To compare prosthetic disc and vertebral distraction stabilization in dogs with disc-associated cervical spondylomyelopathy (DA-CSM).
Study Design: A retrospective clinical study.
Animals: 25 dogs.
Methods: Dogs presenting with clinical signs and MRI findings compatible with DA-CSM underwent surgery. Implantation of the Adamo's prosthetic disc (PD) or vertebral distraction-stabilization (DS) with intervertebral cage, ventral locking plates, and dorsal transarticular screws was performed. All dogs were followed-up and evaluated clinically for a minimum of 1 year and radiographically for at least 3 months. In particular, we focused on the evaluation of subsidence (the degree of vertebral collapse).
Results: Twenty-five dogs were enrolled: 12 with PD implantation and 13 with DS implantation. Of these, 24 dogs were followed-up at 1 year. Overall, 12 dogs improved (4 PD and 8 DS), eight were stable (4 PD and 4 DS), and four deteriorated (3 PD and 1 DS). Deterioration was more common in PD cases, especially soon after surgery. In a few PD cases, a second surgery was necessary. The most common complication in dogs with DS was discospondylitis. Subsidence was detected in 11 PD and 7 DS dogs. Subsidence was more severe and occurred sooner after surgery in PD cases compared to DS cases. DS cases were more prone to clinical improvement and less prone to subsidence than PD cases in this study. However, the statistical evidence was weak owing to the small sample size.
Conclusion: The preliminary results suggest that prosthetic disc implantation is more prone to clinical and radiographic failures than distraction stabilization.
Clinical Relevance: The DS technique is a valuable surgical option for treating dogs with DA-CSM, with favorable short- and long-term clinical and radiographic outcomes.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9251543 | PMC |
http://dx.doi.org/10.3389/fvets.2022.880018 | DOI Listing |
J Contemp Dent Pract
September 2024
Graduate Program in Dentistry, Federal University of Pelotas, Pelotas, Rio Grande do Sul, Brazil; Department of Dentistry, Radboud Institute for Health Sciences, Radboud University Medical Center, Nijmegen, The Netherlands, ORCID: https://orcid.org/0000-0002-5166-8233.
Aim: This study aimed to assess if the addition of origanum oil to denture materials could decrease microorganisms counts and biofilm formation without changing their mechanical/surface properties.
Materials And Methods: A total of 66 resilient denture liner discs (SoftConfort, Dencril Comércio de Plásticos Ltda, SP, Brazil) were prepared with fixed dimensions of 10 × 3 mm for biofilm assay ( = 36) and 12 × 2 mm for sorption-solubility tests ( = 30) containing three oil concentrations - 0, 2.5 and 5%, thereby = 12 per each group samples for biofilm assay and = 10 per each group for sorption-solubility test respectively.
IDCases
December 2024
Division of Infectious Diseases, Department of Medicine, University of Kansas, Kanas City, KS, USA.
A 55-year-old-male with a chronic left uretero-pelvic junction (UPJ) obstruction managed with intermittent stent exchanges presented with low midline back pain. CT Abdomen/Pelvis revealed spondylodiscitis at L4-L5, further demonstrated on MRI Lumbar spine. Imaging also revealed the left nephro-ureteral stent was mispositioned, with some mild wall thickening of the left ureter.
View Article and Find Full Text PDFCureus
November 2024
Internal Medicine, Shri Ram Murti Smarak Institute of Medical Sciences, Bareilly, IND.
Introduction The study aimed to retrospectively evaluate the early patient outcome and left ventricular function after mitral valve replacement with a tilting disc valve and total preservation. Patients and methods This retrospective observational study includes patients who underwent mitral valve replacement using a tilting disc valve with total preservation of mitral valvular and subvalvular apparatus from July 2021 to August 2022 at a single center. Results The data were reviewed retrospectively for age, sex, comorbidities, operating time, aortic cross-clamp time, cardiopulmonary bypass time, preoperative and postoperative left ventricular ejection fraction, mean gradient across the mitral valve, left ventricular diameter, left atrial size, atrial fibrillation, complications, mortality, and early patient outcome.
View Article and Find Full Text PDFCureus
November 2024
General Dentistry and Comprehensive Care, NYU College of Dentistry, New York University, New York, USA.
Objectives To assess the influence of cigarette smoke (CS) on the color and surface roughness of 3D printed, milled, and traditionally fabricated provisional crown and bridge (PC&B) materials. Materials and methods 112 disc-shaped samples were made employing four techniques and materials (28 per group) to fabricate PC&B prostheses. Specimens were fabricated using standard protocols, such as 3D printing, milling, conventional bis-acrylic resin, and traditional autopolymerizing polymethyl methacrylate (PMMA) resin.
View Article and Find Full Text PDFInt Orthod
December 2024
Department of Surgical Sciences (DISC), Division of Prosthetic Dentistry, University of Genoa, Genoa, Italy.
Introduction: The aim of this systematic review was to determine the best treatment alternatives for patients with maxillary lateral incisor agenesis (MLIA) by comparing orthodontic space closure, implant and tooth supported dental prostheses by assessing studies that evaluated their periodontal, occlusal (function) and aesthetic results.
Methods: The present systematic review was reported according to the indications of the preferred reporting items for systematic reviews and meta-analysis (PRISMA) incorporating network meta-analysis, and the protocol was registered with PROSPERO (CRD42023487245). The PRISMA systematic search, without restriction on language or initial date, was carried out using electronic databases: MEDLINE (PubMed), Scopus and central register of controlled trials.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!