A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Effects of Vibration Resistance Exercises on EMG and Skeletal Muscle Hemodynamics. | LitMetric

Effects of Vibration Resistance Exercises on EMG and Skeletal Muscle Hemodynamics.

Am J Health Behav

Chun-Feng Huang, Department of Leisure Services Management, Chaoyang University of Technology, Taichung, Taiwan, Republic of China and Department of Family Medicine, National Yang Ming Chiao Tung University Hospital, Yilan City, Taiwan, Republic of China;, Email:

Published: June 2022

Past studies show that vibration can stimulate muscle activity and improve muscle performance. However, further verification is needed on the effects of different vibration frequencies combined with different muscle strength exercise intensities on EMG activity and skeletal muscle hemodynamics. We recruited 27 male college athletes for 40%, 60%, and 80% maximum voluntary contraction (MVC) tests at the vibration frequencies of 0 Hz, 10 Hz, 20 Hz, and 30 Hz. We collected EMG activity signals using wireless EMGs and skeletal muscle hemodynamic parameters using a near-infrared spectrometer. At an 80% MVC intensity of the rectus femoris, the mean, peak, and area of EMG at 30 Hz were significantly increased, compared with those at 0 Hz. At a 40% MVC intensity with vibration frequencies of 10 Hz, 20 Hz, and 30 Hz, the HHb of skeletal muscles was significantly increased, while the O2Hb and TSI were significantly decreased, compared with those at 0 Hz. We conclude that high frequency and strongly vibrated muscle strength exercise can improve EMG activity, while vibration and low-intensity muscle strength exercise could increase the oxygen consumption of skeletal muscles.

Download full-text PDF

Source
http://dx.doi.org/10.5993/AJHB.46.3.6DOI Listing

Publication Analysis

Top Keywords

skeletal muscle
12
vibration frequencies
12
muscle strength
12
strength exercise
12
emg activity
12
effects vibration
8
muscle
8
muscle hemodynamics
8
mvc intensity
8
skeletal muscles
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!