A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Modular Fluted Tapered Stems for Periprosthetic Femoral Fractures: Excellent Results in 171 Cases. | LitMetric

Background: Modular fluted tapered (MFT) stems have advanced treatment of Vancouver B2 and B3 periprosthetic femoral fractures, but series to date have been limited with respect to cohort size and follow-up duration. The purpose of this study was to determine implant survivorship, radiographic results, complications, and clinical outcomes of Vancouver B2 and B3 periprosthetic femoral fractures treated with MFT stems in a large series of patients.

Methods: We identified 171 Vancouver B2 (109) and B3 (62) periprosthetic femoral fractures treated with an MFT stem between 2000 and 2018 using our institutional total joint registry. The mean age was 75 years, 50% were female, and the mean body mass index was 29 kg/m2. The median stem diameter was 18 mm and median stem length was 210 mm. The cumulative incidences of revision and reoperation with death as the competing risk were calculated, radiographs were reviewed, and clinical outcomes were evaluated using the Harris hip score (HHS). The mean follow-up was 5 years.

Results: The 10-year cumulative incidence of any revision was 10%. There were 17 revisions, of which only 3 were for the distal fluted portion of the MFT stem. Revision indications included periprosthetic joint infection (PJI) (n = 6) and dislocation (n = 11). The 10-year cumulative incidence of any reoperation was 15%. In addition to the above 17 revisions, there were 7 reoperations for superficial wound complications (n = 4), Vancouver B1 periprosthetic femoral fracture (n = 1), vascular occlusion (n = 1), and acetabular cartilage degeneration requiring an acetabular component (n = 1). Radiographically, there was 1 fracture nonunion. All unrevised MFT stems were radiographically well fixed. Subsidence of ≥5 mm occurred in 11%, but all implants were stable at the most recent follow-up. The mean HHS was 75 at 2 years (n = 71).

Conclusions: In this large series of 171 Vancouver B2 and B3 periprosthetic femoral fractures treated with MFT stems, we found that such constructs were associated with a high rate of fracture healing and provided extremely reliable and durable implant fixation, with no revisions for aseptic loosening. Dislocation and PJI were the most common complications.

Level Of Evidence: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

Download full-text PDF

Source
http://dx.doi.org/10.2106/JBJS.21.01168DOI Listing

Publication Analysis

Top Keywords

periprosthetic femoral
24
femoral fractures
20
mft stems
16
vancouver periprosthetic
16
fractures treated
12
treated mft
12
modular fluted
8
fluted tapered
8
clinical outcomes
8
large series
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!