A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

iQMetrix-CT: New software for task-based image quality assessment of phantom CT images. | LitMetric

iQMetrix-CT: New software for task-based image quality assessment of phantom CT images.

Diagn Interv Imaging

Department of Radiology, APHP, Hôpital Tenon, 75020 Paris, France; Institute of Computing and Data Sciences (ISCD), Sorbonne Université, 75013 Paris, France.

Published: November 2022

The purpose of this article was to explain how the new iQMetrix-CT software works, as well as to describe its current potential and discuss its future applications. iQMetrix-CT was developed by a working group from the French Society of Medical Physicists (SFPM). This software calculates three advanced metrics, which have been adapted to take into account the non-linear and non-stationary properties of iterative reconstruction algorithms. Noise power spectrum is calculated to assess noise texture and noise magnitude in the frequency domain. The task-based transfer function is computed to assess the spatial resolution under conditions of contrast and noise similar to the lesions encountered in clinical practice. Finally, the detectability index is used to estimate the radiologist's ability to perform a given task such as detecting a simulated lesion. These metrics are very useful to evaluate the performance of reconstruction algorithms in term of image quality and optimize the doses of a given protocol or to evaluate and compare a new technology.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.diii.2022.05.007DOI Listing

Publication Analysis

Top Keywords

iqmetrix-ct software
8
image quality
8
reconstruction algorithms
8
software task-based
4
task-based image
4
quality assessment
4
assessment phantom
4
phantom images
4
images purpose
4
purpose article
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!