Bioprosthetic heart valves (BHVs) have been used widely due to the development of transcatheter heart valve replacement technology. However, glutaraldehyde crosslinked pericardium (GA), which is widely used as a leaflet material for BHVs, still has disadvantages, including cytotoxicity, thrombosis, and calcification, which lead to the dysfunction and degeneration of BHVs. Herein, we prepared a methacrylated arginine-grafted BHV through the copolymerization of methacrylated arginine and methacrylated porcine pericardium (PP). Briefly, PP was crosslinked by glutaraldehyde and methacrylated polylysine (pLy-MA) to obtain methacrylated PP (pLy-GA), and the pLy-GA was then copolymerized with methacrylated arginine to prepare methacrylated arginine-grafted PP (pLy-GA-Arg). The introduction of Arg-MA improved the ability of PP to resist platelet adhesion, and compared with GA, platelet adhesion decreased by 78% which exhibited improved antithrombotic properties. pLy-GA-Arg exhibited improved cytocompatibility and the relative proliferation rate of HUVECs increased by 2 times compared with GA. After 60 days of subcutaneous implantation, the calcification degree of pLy-GA-Arg was significantly lower than that of GA (4.37 ± 0.33 μg mg 157.46 ± 41.74 μg mg). The introduction of arginine improved the hemocompatibility and cytocompatibility of PP and reduced its calcification, offering a potential option for BHV fabrication in the future.

Download full-text PDF

Source
http://dx.doi.org/10.1039/d2tb00798cDOI Listing

Publication Analysis

Top Keywords

porcine pericardium
8
bioprosthetic heart
8
heart valve
8
methacrylated arginine-grafted
8
methacrylated arginine
8
platelet adhesion
8
exhibited improved
8
methacrylated
7
arginine-grafted porcine
4
pericardium copolymerization
4

Similar Publications

The autologous pericardial aortic valve repair technique developed by Ozaki et al., using glutaraldehyde-treated autologous pericardium, has demonstrated superior durability to bioprosthetic valves. However, this technique has certain limitations, including excessive cusp height and cusp fluttering due to leaflet redunduncy.

View Article and Find Full Text PDF

Collagen-based membrane is the most commonly used biomaterial for guided bone and tissue regeneration; however, its barrier function can be threatened by its rapid degradation pattern, affecting the success of the regeneration process. Differences in the origin and functionalization of the membrane to obtain better properties can alter the degradation rate. The objective of this study was to examine the biodegradation pattern of two commercially available collagen membranes (Jason and Collprotect) manufactured using porcine pericardium or dermis, doped or not with zinc-ions or doxycycline, in a period up to 21 days.

View Article and Find Full Text PDF

Valve replacement is the most effective means of treating heart valve diseases, and transcatheter heart valve replacement (THVR) is the hottest field at present. However, the durability of the commercial bioprosthetic valves has always been the limiting factor restricting the development of interventional valve technology. The chronic inflammatory reaction, calcification, and difficulty in endothelialization after the implantation of a glutaraldehyde cross-linked porcine aortic valve or bovine pericardium often led to valve degeneration.

View Article and Find Full Text PDF

Objective: Annuloplasty is the most common strategy for repair of functional tricuspid regurgitation (FTR) but is not effective in patients with massive/torrential FTR or leaflet tethering. To address the deficits of tricuspid annuloplasty, TRicuspid Anterior and Posterior Patch (TRAPP) repair was developed, which is a pericardial patch augmentation of the anterior and posterior leaflets.

Methods: To test this repair, a previously validated ex vivo model in an explanted porcine heart was used, wherein annular and leaflet geometry were evaluated using a 3-dimensional structured light scanner at 4 time points: (1) baseline, (2) induction of FTR, (3) annuloplasty repair, and (4) patch repair.

View Article and Find Full Text PDF

Redo isolated tricuspid valve replacement in a patient with isolated persistent left superior vena cava: a case report.

Gen Thorac Cardiovasc Surg Cases

August 2024

Department of Cardiovascular Surgery, Saitama Medical Center, Jichi Medical University, 1-847 Amanumacho, Omiya-ku, Saitama, 330-0834, Japan.

Background: Redo isolated tricuspid valve surgery has high in-hospital mortality and morbidity and is a challenging procedure. We report a successful case of redo isolated tricuspid valve replacement for structural valve deterioration of a bioprosthesis in a patient with isolated persistent left superior vena cava (PLSVC).

Case Presentation: An 81-year-old man with a history of tricuspid valve replacement using a porcine bioprosthetic valve 9 years previously presented with dyspnea on exertion.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!