Proteomics technology is being increasingly used in the development of novel therapeutic peptides and protein drugs, and also in the intensive search for clinical biomacromolecule diagnostic biomarkers. Ultra-performance liquid chromatography-mass spectrometry (UPLC-MS) is a rapid method to analyze peptides and proteins in low abundance. However, the nonspecific adsorption properties of peptides may lead to the loss or interference of the analytes throughout the analytical process. This unique nonspecific adsorption property is the main reason for the false negative and false positive results obtained through quantification, as well as for the poor precision, accuracy, linear range, and sensitivity, all of which impose significant challenges in the development of analytical methods. Accordingly, a general strategy was established to evaluate and reduce the negative impact of the nonspecific adsorption of peptides on UPLC-MS analysis. In this study, bovine serum albumin (BSA) was used as a model protein to explore the correlation between the physicochemical properties of 50 peptides obtained by the enzymatic digestion of BSA, as well as the degree of nonspecific adsorption. First, these peptides were classified into four categories according to their response and the degree of adsorption in the pretreatment containers and LC system. Next, the factors influencing the adsorption of 12 Class Ⅱ peptides, which were highly responsive and susceptible to adsorption, were systematically studied in terms of several aspects, including: (1) time-dependent adsorption on centrifuge tubes of three kinds (Protein-LoBind polypropylene tube and two types of polypropylene tubes); (2) time-dependent adsorption on sample vials of three kinds (Protein-LoBind polypropylene vial, polypropylene vial, and glass vial); (3) carryovers on chromatographic columns with six different stationary phases (Polar C, Cortecs C, PFP, BEH C, CSH C, and BEH C); (4) carryovers at different chromatographic gradients (2%B-30%B, 2%B-40%B, 2%B-50%B, and 2%B-60%B within 3 min), flow rates (0.2, 0.3, and 0.4 mL/min), and column temperatures (30, 40, 50, and 60 ℃); and (5) carryovers using different washing needle solutions (0.2% formic acid in 10% acetonitrile and 0.2% formic acid in 90% acetonitrile). The results showed that parameters such as the HPLC index and amino acid length of peptides were significantly correlated with their degree of adsorption (<0.05), However, the above parameters can only explain the adsorption degree of 30% of the peptides. The use of the modified polypropylene material resulted in higher recovery (recovery rate>80% within 24 h) of the peptide solution during storage or pretreatment. During protein/peptide pretreatment and storage, good overall recoveries (recovery rate>80% within 24 h) were obtained using centrifuge tubes and sample vials made of the modified polypropylene material. Analysis and optimization of the LC conditions revealed that the use of the C chromatographic column, a high flow rate (0.4 mL/min), slow gradient (2%B-50%B within 3 min), and strong needle solution (0.2% formic acid in 90% acetonitrile) could minimize the carryover. However, the effect of the column temperature on the carryover varied considerably from peptide to peptide, and hence, requires further analysis for specific peptides. The combined optimization of the above experimental conditions resulted in minimal (approximately 1/150) or no adsorption of the Class Ⅱ peptides that were susceptible to adsorption in the analytical process. In this study, a workflow was designed to standardize the procedures for evaluating and reducing peptide adsorption. Detailed data were collected to elucidate the key risk factors and corresponding general mechanism of nonspecific adsorption throughout the analysis. Thus, this study serves as a reference for the development of analytical methods for peptides and proteins with different physicochemical properties. In future work, the risk factors should be assessed during the development and validation of protein-based macromolecular analysis methods. In conclusion, it is important to implement adequate and appropriate measures to ensure risk elimination or minimization.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9404093PMC
http://dx.doi.org/10.3724/SP.J.1123.2021.12012DOI Listing

Publication Analysis

Top Keywords

nonspecific adsorption
20
adsorption
14
02% formic
12
formic acid
12
peptides
11
ultra-performance liquid
8
liquid chromatography-mass
8
peptides proteins
8
properties peptides
8
analytical process
8

Similar Publications

One-step antifouling coating of polystyrene using engineered polypeptides.

J Colloid Interface Sci

January 2025

Physical Chemistry and Soft Matter, Wageningen University & Research, Stippeneng 4 6708 WE Wageningen, The Netherlands. Electronic address:

Unwanted nonspecific adsorption caused by biomolecules influences the lifetime of biomedical devices and the sensing performance of biosensors. Previously, we have designed B-M-E triblock proteins that rapidly assemble on inorganic surfaces (gold and silica) and render those surfaces antifouling. The B-M-E triblock proteins have a surface-binding domain B, a multimerization domain M and an antifouling domain E.

View Article and Find Full Text PDF

Autonomous Anticoagulation on a Biomimetic Al-Based Hierarchical Surface.

ACS Appl Mater Interfaces

January 2025

Key Laboratory of Bionic Engineering Ministry of Education, Jilin University, Changchun 130025, China.

Studies targeting the blood repellency and autonomous anticoagulation of superhydrophobic (SH) surfaces are potentially valuable for their application in blood contact. The anticoagulation abilities and potential mechanisms of different SH surfaces urgently need to be revealed. In this study, a range of microprotrusion arrays on Al substrates with varying spacings via laser ablation through the utilization of organic adsorption and siloxane coupling reactions were fabricated.

View Article and Find Full Text PDF

A wearable antifouling electrochemical sensor integrated with an antimicrobial microneedle array for uric acid detection in interstitial fluid.

Anal Chim Acta

February 2025

Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, MOE, Shandong Key Laboratory of Biochemical Analysis, College of Chemistry and Molecular Engineering, Qingdao University of Science & Technology, Qingdao, 266042, China. Electronic address:

Wearable microneedle array (MNA) based electrochemical sensors have gained increasing attention for their capability to analyze biomarkers in the interstitial fluid (ISF), enabling noninvasive, continuous monitoring of health parameters. However, challenges such as nonspecific adsorption of biomolecules on the sensor surfaces and the risk of infection at the microneedle penetration sites hinder their practical application. Herein, a wearable dual-layer microneedle patch was prepared to overcome these issues by integrating an antimicrobial microneedle layer with an antifouling sensing layer.

View Article and Find Full Text PDF

Herein, we present an efficient approach for developing electrochemical aptasensing interfaces, by "click" postfunctionalization of phenylethynyl-grafted glassy carbon substrates with mixed monolayers containing biorecognition elements and phosphorylcholine zwitterionic groups. Typically, controlling the composition of multicomponent surface layers by grafting from a mixture of aryldiazonium salts is challenging due to differences in their chemical reactivity. Our approach circumvents this issue by employing the electrochemical reduction of a single aryldiazonium salt containing a silyl-protected alkyne group followed by deprotection, to create phenylethynyl monolayers which can subsequently accommodate the concurrent immobilization of bioreceptors and zwitterionic groups through "click" postfunctionalization.

View Article and Find Full Text PDF

Integrating Protein Language Model and Molecular Dynamics Simulations to Discover Antibiofouling Peptides.

Langmuir

January 2025

Department of Chemical and Materials Engineering, University of Kentucky, Lexington, Kentucky 40506, United States.

Antibiofouling peptide materials prevent the nonspecific adsorption of proteins on devices, enabling them to perform their designed functions as desired in complex biological environments. Due to their importance, research on antibiofouling peptide materials has been one of the central subjects of interfacial engineering. However, only a few antibiofouling peptide sequences have been developed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!