A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Gold-dispersed hierarchical flower-like copper oxide microelectrodes for the sensitive detection of glucose and lactic acid in human serum and urine. | LitMetric

Herein, we report self-supported gold-dispersed copper oxide microflowers (Au@CuO MFs) on copper microelectrodes (CMEs) as a sensitive platform for the sensing of glucose and lactic acid in human serum and urine samples. The direct growth of a new class of gold-dispersed copper oxide microflowers on Cu microelectrodes involves growing flower-like passivated copper microelectrodes in nitric acid followed by the galvanic replacement of copper atoms with gold atoms without employing any surfactant or polymer or without the use of any catalysts or complicated procedures. The as-fabricated gold-dispersed copper oxide microflower microelectrodes (Au@CuO MFs|CME) were employed as potential signal transducers for the sensitive detection of glucose and lactic acid in practical samples. The present Au@CuO MFs|CME microsensor demonstrates an extensive linear detection range from 5.0 μM to 0.5 mM for glucose with a low limit of detection (LOD) of ∼1.41 μM and a sensitivity of ∼4.14 mA μM cm, and from 100 nM to 88.0 μM for lactic acid with a LOD of ∼27.0 nM and a sensitivity of ∼6.19 mA μM cm. The present multi-functional nanoarchitectured Au@CuO MFs|CME microsensor is anticipated to offer unique surface characteristics and synergistic effects, and can be exploited in various electrochemical fields.

Download full-text PDF

Source
http://dx.doi.org/10.1039/d2bm00527aDOI Listing

Publication Analysis

Top Keywords

copper oxide
16
lactic acid
16
glucose lactic
12
gold-dispersed copper
12
au@cuo mfs|cme
12
sensitive detection
8
detection glucose
8
acid human
8
human serum
8
serum urine
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!