Electronic visual prostheses, or biomimetic eyes, have shown the feasibility of restoring functional vision in the blind through electrical pulses to initiate neural responses artificially. However, existing visual prostheses predominantly use wired connections or electromagnetic waves for powering and data telemetry, which raises safety concerns or couples inefficiently to miniaturized implant units. Here, we present a flexible ultrasound-induced retinal stimulating piezo-array that can offer an alternative wireless artificial retinal prosthesis approach for evoking visual percepts in blind individuals. The device integrates a two-dimensional piezo-array with 32-pixel stimulating electrodes in a flexible printed circuit board. Each piezo-element can be ultrasonically and individually activated, thus, spatially reconfigurable electronic patterns can be dynamically applied via programmable ultrasound beamlines. As a proof of concept, we demonstrate the ultrasound-induced pattern reconstruction in ex vivo murine retinal tissue, showing the potential of this approach to restore functional, life-enhancing vision in people living with blindness.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9253314 | PMC |
http://dx.doi.org/10.1038/s41467-022-31599-4 | DOI Listing |
J Clin Med
January 2025
Department of Orthopedics and Traumatology, Private Medicabil Hospital, 16140 Nilüfer/Bursa, Türkiye.
: Developmental dysplasia of the hip (DDH), defined by the malalignment of the femoral head and acetabulum, is a major precursor to coxarthrosis, posing substantial challenges during total hip arthroplasty (THA). Patients with coxarthrosis secondary to DDH often exhibit acetabular bone insufficiency, which makes challenging surgical reconstruction difficult. This study aimed to compare the radiologic and functional outcomes of robotically assisted and conventional manual THA techniques in patients with coxarthrosis secondary to Crowe type III-IV DDH.
View Article and Find Full Text PDFThe purpose of the present study was to evaluate and compare the clinical outcomes of two groups of patients subject to bi-cruciate retaining (BCR) or posterior-stabilized (PS) implants. It was hypothesized that patients treated with BCR prostheses would present higher flexion and better clinical and functional results than those treated with PS implants. This prospective study included thirty-two patients treated for primary knee osteoarthritis and assigned to two matched groups for their demographic characteristics and comorbidities.
View Article and Find Full Text PDFZhongguo Xiu Fu Chong Jian Wai Ke Za Zhi
January 2025
Department of Artificial Joint Revision, Luoyang Orthopedic-Traumatological Hospital of Henan Province (Henan Provincial Orthopedic Hospital), Zhengzhou Henan, 450003, P. R. China.
Objective: To analyze the short-term effectiveness and safety of personalized three-dimensional (3D) printed customized prostheses in severe Paprosky type Ⅲ acetabular bone defects.
Methods: A retrospective analysis was conducted on 8 patients with severe Paprosky type Ⅲ acetabular bone defects and met the selection criteria between January 2023 and June 2024. There were 3 males and 5 females, with an average age of 64.
J Orthop Surg Res
January 2025
Department of Orthopedic, Taizhou Hospital of Zhejiang Province Affiliated to Wenzhou Medical University, Taizhou, Zhejiang, China.
Knee arthritis is a common degenerative joint disease, usually with joint swelling, chronic pain, and dysfunction as the main clinical manifestations. At present, the conservative treatment for knee arthritis is mostly using anti-inflammatory and analgesic drugs, but the effect is mostly temporary, and can not prevent its progress and surgery is usually the last treatment method. Total knee arthroplasty, also known as TKA, is one of the most effective treatments for osteoarthritis of the knee that has progressed to the end stage.
View Article and Find Full Text PDFHeliyon
January 2025
Ophthalmology Unit, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy.
Purpose: To evaluate the intermediate-term visual and safety outcomes of the small-incision second-generation implantable miniature telescope (SING IMT) in patients with late-stage age-related macular degeneration (AMD) at 6 months post-surgery.
Design: Retrospective cohort study.
Methods: Medical records of patients implanted with the SING IMT at two sites in Italy were reviewed.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!