Recent years have seen rapid advancements in the way that personality is measured, resulting in a number of innovative predictive measures being proposed, including using features extracted from videos and social media profiles. In the context of selection, game- and image-based assessments of personality are emerging, which can overcome issues like social desirability bias, lack of engagement and low response rates that are associated with traditional self-report measures. Forced-choice formats, where respondents are asked to rank responses, can also mitigate issues such as acquiescence and social desirability bias. Previously, we reported on the development of a gamified forced-choice image-based assessment of the Big Five personality traits created for use in selection, using Lasso regression for the scoring algorithms. In this study, we compare the machine-learning-based Lasso approach to ordinary least squares regression, as well as the summative approach that is typical of forced-choice formats. We find that the Lasso approach performs best in terms of generalisability and convergent validity, although the other methods have greater discriminate validity. We recommend the use of predictive Lasso regression models for scoring forced-choice image-based measures of personality over the other approaches. Potential further studies are suggested.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.actpsy.2022.103659 | DOI Listing |
Acta Psychol (Amst)
August 2022
Institute of Management Studies, Goldsmiths, University of London, New Cross, London SE14 6NW, UK; HireVue, London, UK.
Recent years have seen rapid advancements in the way that personality is measured, resulting in a number of innovative predictive measures being proposed, including using features extracted from videos and social media profiles. In the context of selection, game- and image-based assessments of personality are emerging, which can overcome issues like social desirability bias, lack of engagement and low response rates that are associated with traditional self-report measures. Forced-choice formats, where respondents are asked to rank responses, can also mitigate issues such as acquiescence and social desirability bias.
View Article and Find Full Text PDFJ Intell
February 2022
Institute of Management Studies, Goldsmiths, University of London, New Cross, London SE14 6NW, UK.
Selection methods are commonly used in talent acquisition to predict future job performance and to find the best candidates, but questionnaire-based assessments can be lengthy and lead to candidate fatigue and poor engagement, affecting completion rates and producing poor data. Gamification can mitigate some of these issues through greater engagement and shorter testing times. One avenue of gamification is image-based tests.
View Article and Find Full Text PDFRadiology
November 2018
From the Departments of Radiology (A.M., D.A.Z., A.M.A., P.B., J.C., S.M.C., M.K.D., M.L.G., S.K., O.K., J.H.L., M.M., A.N., R.B.O., U.P.S., E.V.S., G.V.T., C.L.W., K.M.K.) and Bioengineering (C.P., J.L.), University of Washington School of Medicine, Box 357115, 1959 NE Pacific St, Seattle, WA 98195; and Department of Radiology, University of Colorado-Denver, Aurora, Colo (J.H.M.).
Purpose To investigate performance in detectability of small (≤1 cm) low-contrast hypoattenuating focal lesions by using filtered back projection (FBP) and iterative reconstruction (IR) algorithms from two major CT vendors across a range of 11 radiation exposures. Materials and Methods A low-contrast detectability phantom consisting of 21 low-contrast hypoattenuating focal objects (seven sizes between 2.4 and 10.
View Article and Find Full Text PDFIEEE Trans Med Imaging
November 2017
This paper proposes a new method of simulating dose reduction in digital breast tomosynthesis, starting from a clinical image acquired with a standard radiation dose. It considers both signal-dependent quantum and signal-independent electronic noise. Furthermore, the method accounts for pixel crosstalk, which causes the noise to be frequency-dependent, thus increasing the simulation accuracy.
View Article and Find Full Text PDFMed Phys
May 1995
Center for Imaging Science, Rochester Institute of Technology, New York 14623-5604, USA.
The receiver operating characteristic (ROC) method has been successfully used in medical imaging for 20 years. It has been so successful that many people think of it as an end in itself rather than just one of several ways to assess human observer performance of image based decision tasks. Studies of human and ideal observer decision performance are designed to estimate a measure of observer performance (e.