Ion beam figuring with focused anode layer thruster.

Rev Sci Instrum

Institute of Plasma Technologies, Korea Institute of Fusion Energy, 37 Dongjangsan-ro, 54004 Gunsan-si, Jeollabuk-do, Republic of Korea.

Published: June 2022

This work presents the peculiarities of cone ion beam formation with a focused thruster with anode layer (TAL) and its application to silicon carbide (SiC) ion beam figuring. Modeling results of Lorentz E × B force distribution in the discharge gap are presented. 3D particle tracing for keV Ar ions is carried out for the first time in the beam drift region of TAL with magnetic lens. Extracted ion beam full width at half maxima is about 2 mm in the focal plane, where the SiC etching rate reaches 0.5 µm/min. The SiC sputter yields are measured as a function of the Ar ion impact energy and beam incidence angle. The maximum sputter yield of 2.8 atom/ion is observed at 45° of the beam-sample angle for the Si targets. Furthermore, the maximum sputter yield value of 1.7 atom/ion is measured at 30° of the beam-sample angle for the SiC targets. The novelty of present research is in the application of focused TAL keV Ar ion beam to the SiC ion beam figuring.

Download full-text PDF

Source
http://dx.doi.org/10.1063/5.0071800DOI Listing

Publication Analysis

Top Keywords

ion beam
24
beam figuring
12
anode layer
8
sic ion
8
maximum sputter
8
sputter yield
8
yield atom/ion
8
beam-sample angle
8
ion
7
beam
7

Similar Publications

Growth of lithium whiskers or dendrites is the major obstacle towards safe and stable utilization of lithium metal anodes in rechargeable batteries. In this study, we look deeper into the mechanism of lithium electrodeposition. We find that before lithium whisker or dendrite nucleation occurs, lithium is deposited into the grain boundaries of the metal electrode, which we directly observed in the focused ion beam cross-sections of the lithium electrode.

View Article and Find Full Text PDF

Fabry-Perot (FP) lasers with a cavity length shorten down to 50 µm were investigated. One or two laser mirrors were formed by focused ion beam etching. InGaAs quantum dots of high density were used as the laser active region.

View Article and Find Full Text PDF

Accurate dose predictions are crucial to maximizing the benefits of carbon-ion therapy. Carbon beams incident on the human body cause nuclear interactions with tissues, resulting in changes in the constituent nuclides and leading to dose errors that are conventionally corrected using conventional single-energy computed tomography (SECT). Dual-energy computed tomography (DECT) has frequently been used for stopping power estimation in particle therapy and is well suited for correcting nuclear reactions because of its detailed body-tissue elemental information.

View Article and Find Full Text PDF

The increasing interest in hadron therapy has heightened the need for accurate and reliable methods to assess radiation quality and the biological effectiveness of particles used in treatment. Microdosimetry has emerged as a key tool for this, demonstrating its potential, reliability, and suitability. In this context, solid-state microdosimeters offer technological advantages over traditional Tissue-Equivalent Proportional Counters, and recent advancements have further improved their performance and reliability.

View Article and Find Full Text PDF

Ultrasmall micro-light-emitting diodes (μLEDs), sized below 10 μm, are indispensable to create the next-generation augmented and virtual reality (AR/VR) devices. Their high brightness and low power consumption could not only enhance the user experience by providing vivid and lifelike visuals but also extend device longevity. However, a notable challenge emerges: a decrease in efficiency with a reduced size.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!