In mass spectrometry (MS)-based quantitative proteomics, labeling with isobaric mass tags such as iTRAQ and TMT can substantially improve sample throughput and reduce peptide missing values. Nonetheless, the quantification of labeled peptides tends to suffer from reduced accuracy due to the co-isolation of co-eluting precursors of similar mass-to-charge. Acquisition approaches such as multistage MS3 or ion mobility separation address this problem, yet are difficult to audit and limited to expensive instrumentation. Here we introduce IsobaricQuant, an open-source software tool for quantification, visualization, and filtering of peptides labeled with isobaric mass tags, with specific focus on precursor interference. IsobaricQuant is compatible with MS2 and MS3 acquisition strategies, has a viewer that allows assessing interference, and provides several scores to aid the filtering of scans with compression. We demonstrate that IsobaricQuant quantifications are accurate by comparing it with commonly used software. We further show that its QC scores can successfully filter out scans with reduced quantitative accuracy at MS2 and MS3 levels, removing inaccurate peptide quantifications and decreasing protein CVs. Finally, we apply IsobaricQuant to a PISA dataset and show that QC scores improve the sensitivity of the identification of protein targets of a kinase inhibitor. IsobaricQuant is available at https://github.com/Villen-Lab/isobaricquant.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9894126 | PMC |
http://dx.doi.org/10.1002/pmic.202100253 | DOI Listing |
Sci Rep
December 2024
Pharmacy Department, Hospices Civils de Lyon, Hôpital E. Herriot, Plateforme FRIPHARM, 69437, Lyon, France.
Phage therapy uses viruses (phages) against antibiotic resistance. Tailoring treatments to specific patient strains requires stocks of various highly concentrated purified phages. It, therefore, faces challenges: titration duration and specificity to a phage/bacteria couple; purification affecting stability; and highly concentrated suspensions tending to aggregate.
View Article and Find Full Text PDFFront Public Health
December 2024
Wastewater Technology Research, Wastewater Disposal, German Environment Agency, Berlin, Germany.
Introduction: Accurate and consistent data play a critical role in enabling health officials to make informed decisions regarding emerging trends in SARS-CoV-2 infections. Alongside traditional indicators such as the 7-day-incidence rate, wastewater-based epidemiology can provide valuable insights into SARS-CoV-2 concentration changes. However, the wastewater compositions and wastewater systems are rather complex.
View Article and Find Full Text PDFTalanta
December 2024
Institute of Biomedical Precision Testing and Instrumentation, College of Artificial Intelligence, Taiyuan University of Technology, Taiyuan, Shanxi, 030600, PR China.
Developing a fluorescence sensing platform for point-of-care detection of low abundance biomarkers is highly valuable for early diagnosis of disease. Herein, a biomimetic fluorescence-enhanced platform based on photonic crystals and DNAzyme walker was constructed and further applied to visualize and quantify the miRNA-21 in biological samples. The DNAzyme walker was orthogonally activated by the target miRNA-21, which enabled the unlocking of the DNAzyme walker strand and the subsequently repeated substrate cleavage, thus generating enhanced fluorescence signals.
View Article and Find Full Text PDFJ Clin Neurophysiol
December 2024
Department of Neurology, Wake Forest University School of Medicine, Winston-Salem, North Carolina, U.S.A.
Purpose: High-frequency ultrasound (HFUS) of muscle and nerve has the potential to be a reliable, responsive, and informative biomarker of disease progression for individuals with amyotrophic lateral sclerosis (ALS). High-frequency ultrasound is not able to visualize median nerve fascicles to the same extent as ultra-high-frequency ultrasound (UHFUS). Evaluating the number and size of fascicles within a nerve may facilitate a better understanding of nerve diseases.
View Article and Find Full Text PDFInvest Radiol
October 2024
From the Institute for Diagnostic and Interventional Radiology, University Hospital Zurich, University Zurich, Zurich, Switzerland (B.K., F.E., J.K., T.F., L.J.); Advanced Radiology Center, Department of Diagnostic Imaging and Oncological Radiotherapy, Fondazione Policlinico Universitario "A. Gemelli" IRCCS, Rome, Italy (C.S., A.R.L.); and Section of Radiology, Department of Radiological and Hematological Sciences, Università Cattolica del Sacro Cuore, Rome, Italy (A.R.L.).
Objectives: The aim of this study was to evaluate the feasibility and efficacy of visual scoring, low-attenuation volume (LAV), and deep learning methods for estimating emphysema extent in x-ray dose photon-counting detector computed tomography (PCD-CT), aiming to explore future dose reduction potentials.
Methods: One hundred one prospectively enrolled patients underwent noncontrast low- and chest x-ray dose CT scans in the same study using PCD-CT. Overall image quality, sharpness, and noise, as well as visual emphysema pattern (no, trace, mild, moderate, confluent, and advanced destructive emphysema; as defined by the Fleischner Society), were independently assessed by 2 experienced radiologists for low- and x-ray dose images, followed by an expert consensus read.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!