A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Surgical Fixation of Three- and Four-Part Proximal Humeral Fractures Using the Proximal Humeral Interlocking System Plate. | LitMetric

Introduction The management of proximal humeral fractures ranges greatly from conservative management to surgical treatment. For those fractures requiring surgical treatment, internal fixation is the primary method. The aim of internal fixation is to achieve rigid fracture fixation until union occurs, return of shoulder range of motion, and minimise intra-and postoperative complications. The aim of this study was to evaluate the results of the Proximal Humeral Interlocking System Plate (PHILOS) used for the treatment of three-and four-part proximal humeral fractures. Materials and methods This study included 30 patients with a mean age of 54 years (range 20-80 years). Results were checked post-operatively with standard radiographs and clinical evaluation according to the Constant-Murley shoulder score. All patients were followed up for 12 months. Results Union was achieved in all patients with a mean neck/shaft angle of 130° (range 108°-150°). The mean Constant-Murley score at the final follow-up was 82.28 (range 67-96) correlating with good results. No patients developed an intraoperative or postoperative vascular injury, wound complications, or avascular necrosis of the humeral head. Conclusion Our study has shown that the surgical treatment of three- and four-part proximal humeral fractures with the use of the PHILOS plate leads to a good functional outcome. It has also demonstrated the PHILOS plate and is an effective system for fracture stabilisation provided the correct surgical technique is used with awareness of potential hardware complications.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9236683PMC
http://dx.doi.org/10.7759/cureus.25348DOI Listing

Publication Analysis

Top Keywords

proximal humeral
24
humeral fractures
16
four-part proximal
12
surgical treatment
12
three- four-part
8
humeral interlocking
8
interlocking system
8
system plate
8
internal fixation
8
philos plate
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!