A Review of Boron Neutron Capture Therapy: Its History and Current Challenges.

Int J Part Ther

Department of Radiation Oncology, Nancy N. and J. C. Lewis Cancer & Research Pavilion, Savannah, GA, USA.

Published: June 2022

Mechanism Of Action: External beam, whether with photons or particles, remains as the most common type of radiation therapy. The main drawback is that radiation deposits dose in healthy tissue before reaching its target. Boron neutron capture therapy (BNCT) is based on the nuclear capture and fission reactions that occur when B is irradiated with low-energy (0.0025 eV) thermal neutrons. The resulting B(n,α)Li capture reaction produces high linear energy transfer (LET) α particles, helium nuclei (He), and recoiling lithium-7 (Li) atoms. The short range (5-9 μm) of the α particles limits the destructive effects within the boron-containing cells. In theory, BNCT can selectively destroy malignant cells while sparing adjacent normal tissue at the cellular levels by delivering a single fraction of radiation with high LET particles.

History: BNCT has been around for many decades. Early studies were promising for patients with malignant brain tumors, recurrent tumors of the head and neck, and cutaneous melanomas; however, there were certain limitations to its widespread adoption and use.

Current Limitations And Prospects: Recently, BNCT re-emerged owing to several developments: (1) small footprint accelerator-based neutron sources; (2) high specificity third-generation boron carriers based on monoclonal antibodies, nanoparticles, among others; and (3) treatment planning software and patient positioning devices that optimize treatment delivery and consistency.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9238127PMC
http://dx.doi.org/10.14338/IJPT-22-00002.1DOI Listing

Publication Analysis

Top Keywords

boron neutron
8
neutron capture
8
capture therapy
8
review boron
4
capture
4
therapy history
4
history current
4
current challenges
4
challenges mechanism
4
mechanism action
4

Similar Publications

Current research trends and hotspots of boron neutron capture therapy: a bibliometric and visualization analysis.

Front Oncol

December 2024

Department of Radiation Oncology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Shenzhen, China.

Purpose: This study aimed to describe the trends, current hotspots, and future directions in boron neutron capture therapy (BNCT) through a bibliometric analysis.

Methods: Articles related to BNCT published before 2023-12-31 were retrieved from the Web of Science Core Collection database. VOSviewer, R, and CiteSpace were used for bibliometric analysis and visualization.

View Article and Find Full Text PDF

This study presents a compact accelerator-driven neutron source design with a thermal neutron port and an epithermal neutron port for Boron Neutron Capture Therapy (BNCT), based on 10 mA 2.5 MeV protons bombarding on a 100 μm thick disc-shaped Li target with a diameter of 10 cm. The moderator consists of 2 parts, the epithermal neutron moderator and the thermal neutron moderator.

View Article and Find Full Text PDF

Fractionated alpha and mixed beam radiation promote stronger pro-inflammatory effects compared to acute exposure and trigger phagocytosis.

Front Cell Neurosci

December 2024

Department of Molecular Biosciences, Centre for Radiation Protection Research, The Wenner-Gren Institute, Stockholm University, Stockholm, Sweden.

Introduction And Methods: Aiming to evaluate safety aspects of a recently proposed approach to target Alzheimer's disease, we mimicked a complex boron neutron capture therapy field using a mixed beam consisting of high- and low-linear energy transfer (LET) radiation, Am alpha particles (α) and/or X-ray radiation respectively, in human microglial (HMC3) cells.

Results: Acute exposure to 2 Gy X-rays induced the strongest response in the formation of γH2AX foci 30 min post irradiation, while α- and mixed beam-induced damage (α:X-ray = 3:1) sustained longer. Fractionation of the same total dose (0.

View Article and Find Full Text PDF

Development of anticoincidence detector specializing in small-angle Compton scattering gamma rays for boron neutron capture therapy.

Appl Radiat Isot

December 2024

Division of Quantum and Radiation Engineering, Graduate School of Engineering, Osaka Metropolitan University, 1-2 Gakuen-cho, Naka-ku, Sakai, Osaka, 599-8570, Japan.

A novel anticoincidence detector is proposed for the measurement of 478 keV gamma radiation for evaluation of boron neutron capture therapy. The Compton continuum around the target photopeak position is effectively suppressed by measuring only the Compton gamma rays scattered at small angles from the primary detector. A numerical evaluation using Monte Carlo simulations estimated an 80% reduction in counts, and the developed prototype detector showed 4% suppression of the Compton continuum of cobalt-60 gamma rays.

View Article and Find Full Text PDF

In this study, the gamma radiation shielding properties of concrete samples reinforced with 10%, 20%, 30%, 40% and 50% of the cement weight of brass alloy were investigated. To test gamma shielding performance of the samples, mass and linear attenuation coefficients, half and tenth value layers, effective atomic number and radiation protection efficiency parameters were determined experimentally, theoretically and Monte Carlo simulations (GEANT4 and FLUKA). The studies were performed at 11 different gamma energies that range from 59.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!