Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: To evaluate the influence of corneal ablation patterns on the prediction error after cataract surgery in post-myopic-LASIK eyes.
Methods: Eighty-three post-myopic-LASIK eyes of 83 patients that underwent uneventful cataract surgery were retrospectively included. Predicted postoperative spherical equivalence (SE) was calculated for the implanted lens using the Haigis-L and Barrett True-K formula. Prediction error at one month postsurgery was calculated as actual SE minus predicted SE. For each eye, area and decentration of the ablation zone was measured using the tangential curvature map. The associations between prediction errors and corneal ablation patterns were investigated.
Results: The mean prediction error was - 0.83 ± 1.00 D with the Haigis-L formula and - 1.00 ± 0.99 D with the Barrett True-K formula. Prediction error was positively correlated with keratometry (K) value and negatively correlated with ablation zone area using either formula, and negatively correlated with decentration of the ablation zone using the Barrett True-K formula (all P < 0.05). In the K < 37.08 D group, prediction error was negatively correlated with decentration of the ablation zone with both formulas (all P < 0.05). Multivariate analysis showed that with the Haigis-L formula, prediction error was associated with axial length (AL), K value and decentration, and with the Barrett True-K formula, prediction error was associated with AL and decentration (all P < 0.05).
Conclusion: A flatter cornea, larger corneal ablation zone and greater decentration will lead to more myopic prediction error after cataract surgery in post-myopic-LASIK eyes.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9248133 | PMC |
http://dx.doi.org/10.1186/s40662-022-00295-1 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!