A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Construction of dPCR and qPCR integrated system based on commercially available low-cost hardware. | LitMetric

Fluorescent quantitative PCR (qPCR) and digital PCR (dPCR) are two mainstream nucleic acid quantification technologies. However, commercial dPCR and qPCR instruments have a low integration, a high price, and a large footprint. To solve these shortcomings, we introduce a compound PCR system with both qPCR and dPCR functions. All the hardware used in this compound PCR system is commercially available and low-cost, and free software was used to realize the absolute quantification of nucleic acids. The compound PCR provides two working modes. In the qPCR mode, thermal cycling is realized by controlling the reciprocating motion of the axis. The heating rate is 1.25 °C s and the cooling rate is 1.75 °C s. We performed amplification experiments of the PGEM-3zf (+)1 gene. The performance level was similar to commercial qPCR instruments. In the dPCR mode, the heating rate is 0.5 °C s and the cooling rate is 0.6 °C s. We performed the UPE-Q gene amplification and used the sequential actions of the two-dimensional mechanical sliders to scan the reaction products and used the method of regional statistics and back-inference threshold to get test results. The result we got was 1208 copies per μL, which was similar to expectations.

Download full-text PDF

Source
http://dx.doi.org/10.1039/d2an00694dDOI Listing

Publication Analysis

Top Keywords

compound pcr
12
dpcr qpcr
8
commercially low-cost
8
qpcr instruments
8
pcr system
8
heating rate
8
°c cooling
8
cooling rate
8
°c performed
8
rate °c
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!