A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Efficacy of capnographic and bispectral index monitoring on trans-oral therapeutic endoscopy: A prospective observational study. | LitMetric

Background And Aim: Oral therapeutic and invasive endoscopy requires deep sedation to reduce patient distress due to prolonged examination and procedures. The usefulness of capnography and bispectral index (BIS) monitoring in the early hypoxia detection in oral therapeutic and invasive endoscopy has yet to be evaluated. This study aimed to investigate the clinical impact of capnography and BIS monitoring on hypoxic events during oral therapeutic and invasive endoscopic procedures.

Methods: This is a prospective observational study. Trans-oral non-intubated therapeutic and/or invasive endoscopic procedures were performed with conventional monitoring (pulse oximetry, pulse, and blood pressure) as well as additional monitoring (BIS and end-tidal CO concentration). Hypoxia is defined as oxygen saturation of <90% that lasts >15 s. The clinical impact of capnography and BIS monitoring on hypoxic events during oral therapeutic and invasive endoscopic procedures were investigated with the risk factors for hypoxia in each patient.

Results: Patients with hypoxia had significantly more apneas detected using capnography than other patients. The multivariate analysis revealed the detected apnea by capnography as an independent risk factor for hypoxia (odds ratio: 3.48[95% confidence interval: 1.24-9.78], P = 0.02). The BIS was not significantly different as a risk factor for hypoxia; however, per-event analysis revealed significantly decreased BIS values over time in 3 min before hypoxic events.

Conclusions: Apnea detected by capnography was an independent predictor of hypoxia. The BIS value was not associated with hypoxia events; however, it showed a significant downward trend before hypoxia events.

Download full-text PDF

Source
http://dx.doi.org/10.1111/jgh.15932DOI Listing

Publication Analysis

Top Keywords

oral therapeutic
16
therapeutic invasive
16
bis monitoring
12
invasive endoscopic
12
hypoxia
9
prospective observational
8
observational study
8
invasive endoscopy
8
clinical impact
8
impact capnography
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!