Simplified efficiency calibration methods for semiconductor detectors used in criticality dosimetry.

Appl Radiat Isot

Canadian Nuclear Laboratories, 286 Plant Road, Chalk River, ON, K0J 1J0, Canada. Electronic address:

Published: September 2022

"Oversimplified" and "simplified" methods based on true coincidence summing effect used in uncomplicated determination of the photo-peak efficiency of the semiconductor High Purity Germanium (HPGe) detector system are suggested and verified. The methods and calibrated Co radioactive source may be used to commission any HPGe detector to use during potential criticality event. The determined accuracy of the semiconductor HPGe detector system using this method is a few percent (for the detector system used in this study it was ≃8% for "oversimplified" and ≃5% for "simplified" methods accordingly) reasonable, expected, and good enough to use for estimation of neutron dose from irradiated human blood in a potential criticality event. Moreover, if one can experimentally deduce the photo-peak efficiency for Co 1333 keV γ-ray line using the suggested methods, then with a few percent accuracy this efficiency could be also used for 1369 keV γ-ray line in the decay of Na isotope.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.apradiso.2022.110335DOI Listing

Publication Analysis

Top Keywords

hpge detector
12
detector system
12
"simplified" methods
8
photo-peak efficiency
8
potential criticality
8
criticality event
8
methods
5
simplified efficiency
4
efficiency calibration
4
calibration methods
4

Similar Publications

For the purpose of this study, four natural rock samples-namely, diorite, granodiorite, tonalite, and granite-are being investigated about their radiation attenuation. The elemental composition of the rocks was obtained through Energy dispersive X-ray spectroscopy (EDX) which examines the microstructural and localized area elemental analyses of the four rock samples. A Monte Carlo simulation (MCNP) was used to determine and evaluate the investigated samples.

View Article and Find Full Text PDF

Absolute calibration methodology for non-uniform uranium and matrix distributions in large barrels of uranium-bearing solid waste.

Sci Rep

December 2024

Nuclear Safeguards and Physical Protection Department, Egyptian Atomic Energy Authority (EAEA), Cairo, Egypt.

The effective implementation of domestic and international safeguards necessitates verification techniques for Nuclear Materials (NM). Even in the case of very small quantities of NMs, accounting for and analyzing such traces can provide insights into the mass balance of NMs and/or state activities, ensuring consistency in state declarations. This paper proposes and benchmarks an absolute calibration methodology for estimating the uranium-mass content in large-volume barrels (200 L).

View Article and Find Full Text PDF

In this study, the gamma radiation shielding properties of concrete samples reinforced with 10%, 20%, 30%, 40% and 50% of the cement weight of brass alloy were investigated. To test gamma shielding performance of the samples, mass and linear attenuation coefficients, half and tenth value layers, effective atomic number and radiation protection efficiency parameters were determined experimentally, theoretically and Monte Carlo simulations (GEANT4 and FLUKA). The studies were performed at 11 different gamma energies that range from 59.

View Article and Find Full Text PDF

Ionizing radiation plays an essential role across various fields but also poses significant health risks, requiring effective shielding solutions. This study focuses on the photon shielding properties of PbO-reinforced composites, specifically PbO-0, PbO-2, PbO-4, PbO-6, PbO-8, and PbO-10, through experimental measurements of photon energies ranging from 59.5 keV to 1408.

View Article and Find Full Text PDF

Risk assessment and natural radionuclide content in black-sand deposits of North Sinai coast, Egypt.

Appl Radiat Isot

November 2024

Radiation Measurements Department, Main Chemical Laboratories, Cairo, Egypt.

The radioactivity levels and risk factors have been assessed for twenty-eight positions of Black-Sand (BS) surface deposits along the Mediterranean Sea coast of north Sinai, Egypt. Twenty-eight surface samples were collected from six local cities: El Ressa, Abo Sakl, Ghornata, El Arish, El Masaed, and El Rommana. The activity concentration values of the nuclides of the Ra, Th, and K of the collected samples were measured using a P-type HPGe detector with a relative efficiency of ∼100% where it is defined at 1.

View Article and Find Full Text PDF