A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 143

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 994
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3134
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Bending Sensor Based on Controlled Microcracking Regions for Application toward Wearable Electronics and Robotics. | LitMetric

A soft bending sensor based on the inverse pyramid structure is demonstrated, revealing that it can effectively suppress microcrack formation in designated regions, thus allowing the cracks to open gradually with bending in a controlled manner. Such a feature enabled the bending sensor to simultaneously have a wide dynamic range of bending strain (0.025-5.4%), high gauge factor (∼74), and high linearity ( ∼ 0.99). Furthermore, the bending sensor can capture repeated instantaneous changes in strain and various types of vibrations, owing to its fast response time. Moreover, the bending direction can be differentiated with a single layer of the sensor, and using an array of sensors integrated on a glove, object recognition was demonstrated via machine learning. Finally, a self-monitoring proprioceptive ionic electroactive polymer (IEAP) actuator capable of operating in liquid was demonstrated. Such features of our bending sensor will enable a simple and effective way of detecting sophisticated motion, thus potentially advancing wearable healthcare monitoring electronics and enabling proprioceptive soft robotics.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acsami.2c07795DOI Listing

Publication Analysis

Top Keywords

bending sensor
20
bending
8
sensor based
8
sensor
5
based controlled
4
controlled microcracking
4
microcracking regions
4
regions application
4
application wearable
4
wearable electronics
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!