Transcatheter pulmonary valve replacement has been established as a viable alternative approach for patients suffering from right ventricular outflow tract or bioprosthetic valve dysfunction, with excellent early and late clinical outcomes. However, clinical challenges such as stented heart valve deterioration, coronary occlusion, endocarditis, and other complications must be addressed for lifetime application, particularly in pediatric patients. To facilitate the development of a lifelong solution for patients, transcatheter autologous pulmonary valve replacement was performed in an adult sheep model. The autologous pericardium was harvested from the sheep via left anterolateral minithoracotomy under general anesthesia with ventilation. The pericardium was placed on a 3D shaping heart valve model for non-toxic cross-linking for 2 days and 21 h. Intracardiac echocardiography (ICE) and angiography were performed to assess the position, morphology, function, and dimensions of the native pulmonary valve (NPV). After trimming, the crosslinked pericardium was sewn onto a self-expandable Nitinol stent and crimped into a self-designed delivery system. The autologous pulmonary valve (APV) was implanted at the NPV position via left jugular vein catheterization. ICE and angiography were repeated to evaluate the position, morphology, function, and dimensions of the APV. An APV was successfully implanted in sheep J. In this paper, sheep J was selected to obtain representative results. A 30 mm APV with a Nitinol stent was accurately implanted at the NPV position without any significant hemodynamic change. There was no paravalvular leak, no new pulmonary valve insufficiency, or stented pulmonary valve migration. This study demonstrated the feasibility and safety, in a long-time follow-up, of developing an APV for implantation at the NPV position with a self-expandable Nitinol stent via jugular vein catheterization in an adult sheep model.

Download full-text PDF

Source
http://dx.doi.org/10.3791/63661DOI Listing

Publication Analysis

Top Keywords

pulmonary valve
28
nitinol stent
16
valve replacement
12
self-expandable nitinol
12
adult sheep
12
sheep model
12
npv position
12
valve
10
transcatheter pulmonary
8
autologous pericardium
8

Similar Publications

: New-onset postoperative atrial fibrillation (POAF) is the most common complication after cardiac surgery, occurring approximately in one-third of the patients. This study considered all-comer patients who underwent cardiac surgery to build a predictive model for POAF. : A total of 3467 (Center 1) consecutive patients were used as a derivation cohort to build the model.

View Article and Find Full Text PDF

Endoscopic Mitral Surgery in Noonan Syndrome-Case Report and Considerations.

J Clin Med

January 2025

Department of Surgery IV, George Emil Palade University of Medicine, Pharmacy, Science and Technology of Targu Mures, 38 Gheorghe Marinescu Street, 540139 Targu Mures, Romania.

: Totally endoscopic techniques have become increasingly popular in cardiac surgery, with minimally invasive mitral valve repair emerging as an effective alternative to median sternotomy. This approach could be particularly advantageous for patients with Noonan syndrome, who often present with structural thoracic anomalies and other comorbidities like bleeding disorders. Endoscopic mitral valve surgery is rapidly establishing itself as the new standard of care for mitral valve operations, demonstrating both safety and efficacy.

View Article and Find Full Text PDF

The detection of unexpected findings (UF) during CT scans of patients undergoing TAVR is frequent; however, it is unclear whether such findings have a clinical impact on the TAVR pathway. We conducted a retrospective, single-center observational study enrolling patients who were candidates for TAVR. All enrolled patients underwent a CT scan before valve implantation.

View Article and Find Full Text PDF

The Ross procedure continues to be the best procedure to address unrepairable aortic valve pathology, especially in young adults. The Achilles heel of this procedure has been aortic root dilation and the potential need for a reoperation that may be associated with slightly increased risks in addition to the need for intervention on the pulmonary outflow tract. Modifying the Ross procedure by autograft inclusion inside a Dacron graft seems to have the potential advantage of stabilizing the autograft diameter, which may be associated with improved durability and decrease the need for future intervention.

View Article and Find Full Text PDF

We aimed to evaluate the accuracy and reproducibility of right ventricular output (RVO) using different anatomical landmarks: the internal pulmonary valve diameter (PVD) between the valve hinge points (hinge-PVD) according to the traditional technique, and PVD between the valve leaflet tips (tip-PVD). This was a retrospective analysis of prospective collected data. All neonates with echocardiographic measurements of RVO and left ventricular output (LVO) without congenital heart disease, including patent ductus arteriosus and patent foramen ovale > 3 mm, were included.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!