Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Hypertension is a major cause of cardiovascular disease, chronic kidney disease (CKD), and death. Several studies have demonstrated the efficacy of home blood pressure telemonitoring (HBPT) for blood pressure (BP) control and outcomes, but the effects of this intervention remain unclear in patients with CKD.
Objective: To determine the impact of HBPT on cardiovascular-related and kidney disease-related outcomes in patients with CKD.
Design: Systematic review and meta-analysis.
Setting: All studies that met our criteria regardless of country of origin.
Participants: Patients with chronic kidney disease included in studies using HBPT for BP assessment and control.
Measurements: Descriptive and quantitative analysis of our primary and secondary outcomes.
Methods: We searched MEDLINE, Embase, CINAHL Plus, PsycINFO, Cochrane CENTRAL, Web of Science, and gray literature from inception for observational and randomized controlled studies in nondialysis (ND) CKD using HBPT for BP control. We selected studies that used HBPT as intervention (with or without a control arm) for BP control in ND-CKD populations. The primary outcome was change in mean systolic BP (SBP) and mean diastolic BP (DBP).
Results: We selected 7 studies from 1669 articles that were initially identified. Overall, pooled estimates in the mean difference (MD) for SBP and DBP were -8.8 mm Hg; 95% confidence interval (CI): -16.2 to -1.4; = .02 and -2.4 mm Hg; 95% CI: -3.8 to -1.0; < .001, respectively. For studies comparing intervention with usual care (UC), pooled estimate in MD for SBP was -8.0 mm Hg ( = .02) with no significant reduction for DBP (-2.6 mm Hg; = .18). In studies without a UC arm, both SBP and DBP were not significantly reduced ( > .05). The pooled estimate in MD for estimated glomerular filtration rate showed a significant improvement (5.4 mL/min/1.73 m; < .001).
Limitations: Heterogeneity and few available studies for inclusion limited our ability to identify a robust link between HBPT use and BP and kidney function improvement.
Conclusion: Home blood pressure telemonitoring is associated with mild lowering of BP and moderately improved kidney function in patients with CKD. However, larger studies with improved designs and prolonged interventions are still needed to assess the effects of HBPT on patients' outcomes.