Halogenated organic solvents are the most commonly detected pollutants in groundwater and are particularly toxic and harmful. How to separate these dense nonaqueous phase liquid (DNAPL) pollutants efficiently from groundwater has become an important research question. Here, a novel hydrocyclone with annular overflow structure was designed, which eliminated the short-circuit flow of the traditional hydrocyclone and solved the problem of overflow entrainment caused by the enrichment of droplets near the locus of zero vertical velocities (LZVV) into turbulence. The flow field characteristics of this novel hydrocyclone were studied using Computational Fluid Dynamics (CFD) simulation and compared with the traditional hydrocyclone. It was found that the annular gap structure of the novel hydrocyclone increased the tangential velocity of the outer vortex. Moreover, the radius of the LZVV was expanded outward by 0.17 mm, which reduced the possibility of droplets with small particle sizes in the second phase escaping from the overflow pipe. The collective effect was to eliminate the short-circuit flow. This novel hydrocyclone was able to separate DNAPL pollutants with low consumption and high efficiency, across a range of inlet velocity from 4 to 6 m/s. The maximum separation efficiency was 99.91 %. In addition, with trichloroethylene (TCE) as the target pollutant, the maximum volume fraction of the dispersed phase in the hydrocyclone was located on the side wall of the hydrocyclone. Taken together, we believe that this work will provide a low-cost, efficient separation method for the separation of groundwater- contaminated liquid mixtures. Furthermore, it has broad application prospects in the field of heterotopic remediation of groundwater.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.scitotenv.2022.156866 | DOI Listing |
Sci Rep
August 2024
School of Mechanical and Electrical Engineering, Qiqihar University, Qiqihar City, 161006, Heilongjiang Province, China.
This study aims to address the issue of high energy consumption in the hydrocyclone separation process. By introducing a novel slotted overflow pipe structure and utilizing experimental and response surface optimization methods, the optimal parameters were determined. The research results indicate that the number of slots, slot angles, and positioning dimensions significantly influence the performance of the hydrocyclone separator.
View Article and Find Full Text PDFWater Res
June 2024
Brown and Caldwell, Walnut Creek, CA, United States of America.
Densification is a novel intensification strategy with the potential to improve treatment capacity within existing continuous-flow (CF) water resource recovery facilities at low capital and operating costs and at relatively small particle sizes compared to typical aerobic granular sludge (AGS) systems. To achieve densification, biological selection principles derived from selector design and AGS concepts have been coupled with physical selection via hydrocyclones at full-scale CF facilities to promote the growth and retention of granules. This combination lowers the sludge volume index (SVI) through superior sludge settling and paves the way for optimized nutrient removal and energy efficiency in low dissolved oxygen conditions.
View Article and Find Full Text PDFChemosphere
June 2024
Department of Mining, Topography and Structure Technology, Universidad de León, Campus de Vegazana, 24006, León, Spain; European University on Responsible Consumption and Production, Campus de Vegazana, 24006, León, Spain.
We present the Three-Parameter Penalized Attributive Analysis for Upgrading (3PPAA-U) method as a tool for selecting the Best Upgrading Condition (BUC) in process engineering. Conventional approaches tend to consider only maximizing recovery (ε) and minimizing yield (γc); in contrast, the proposed 3PPAA-U introduces and seeks to maximize a third parameter, the grade (λ). This multi-parameter approach has not yet been explored in existing literature.
View Article and Find Full Text PDFEnviron Sci Pollut Res Int
August 2023
National Engineering Research Center of Industrial Wastewater Detoxication and Resource Recovery, East China University of Science and Technology, 130 Meilong Road, Shanghai, 200237, China.
Water Res X
May 2023
Department of Biological Systems Engineering, Virginia Tech, 1230 Washington St. SW, Blacksburg, VA 24061, USA.
This study removes two technical constraints for transitioning full-scale activated sludge infrastructure to continuous flow, aerobic granular sludge (AGS) facilities. The first of these is the loss of treatment capacity as a result of the rapid washout of flocculent sludge inventory and in turn the potential loss of nitrification during initial AGS reactor startup. The second is the physical selector design which currently is limited to either the complex sequencing batch reactor selection or sidestream hydrocyclones.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!