Background: We lack data on the effect of single premature ventricular contractions (PVCs) on the clinical and echocardiographic response after cardiac resynchronization therapy (CRT) device implantation. We aimed to assess the predictive value of PVCs at early, 1 month-follow up on echocardiographic response and all-cause mortality.

Methods: In our prospective, single-center study, 125 heart failure patients underwent CRT implantation based on the current guidelines. Echocardiographic reverse remodeling was defined as a ≥ 15% improvement in left ventricular ejection fraction (LVEF), end-systolic volume (LVESV), or left atrial volume (LAV) measured 6 months after CRT implantation. All-cause mortality was investigated by Wilcoxon analysis.

Results: The median number of PVCs was 11,401 in those 67 patients who attended the 1-month follow-up. Regarding echocardiographic endpoints, patients with less PVCs develop significantly larger LAV reverse remodeling compared to those with high number of PVCs. During the mean follow-up time of 2.1 years, 26 (21%) patients died. Patients with a higher number of PVCs than our median cut-off value showed a higher risk of early all-cause mortality (HR 0.97; 95% CI 0.38-2.48; P = 0.04). However, when patients were followed up to 9 years, its significance diminished (HR 0.78; 95% CI 0.42-1.46; P = 0.15).

Conclusions: In patients undergoing CRT implantation, lower number of PVCs predicted atrial remodeling and showed a trend for a better mortality outcome. Our results suggest the importance of the early assessment of PVCs in cardiac resynchronization therapy and warrant further investigations.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9233778PMC
http://dx.doi.org/10.1186/s12872-022-02725-3DOI Listing

Publication Analysis

Top Keywords

number pvcs
16
cardiac resynchronization
12
resynchronization therapy
12
crt implantation
12
response cardiac
8
pvcs
8
echocardiographic response
8
reverse remodeling
8
all-cause mortality
8
patients
7

Similar Publications

False Alarms in Wearable Cardioverter Defibrillators-A Relevant Issue or an Insignificant Observation.

J Clin Med

December 2024

Department of Cardiology, Angiology and Intensive Care Medicine, Deutsches Herzzentrum der Charité (DHZC), Campus Virchow-Klinikum, Augustenburger Platz 1, 13353 Berlin, Germany.

The wearable cardioverter defibrillator (WCD) has emerged as a valuable tool used for temporary protection from sudden cardiac death. However, since the WCD uses surface electrodes to detect arrhythmias, it is susceptible to inappropriate detection. Although shock conversion rates for the WCD are reported to be high for detected events, its efficacy in clinical practice tends to be degraded by patient noncompliance.

View Article and Find Full Text PDF

Purpose: This is a prospective study aimed to investigate the morphology of left ventricular false tendons (LVFTs) using echocardiography and explore its associations with age, sex, body mass index (BMI), congenital heart structural abnormalities, and premature ventricular contractions (PVCs).

Methods And Results: We analyzed data from 889 individuals who underwent consecutive echocardiograms at our ultrasound department between December 2023 and February 2024. Routine echocardiograms were performed to detect congenital structural abnormalities, with a focus on identifying LVFT.

View Article and Find Full Text PDF

Objective: Treating iron deficiency (ID) with ferric carboxymaltose (FCM) in patients with heart failure with reduced ejection fraction (HFrEF) enhances morbidity, quality of life (QoL), and exercise capacity.

Methods: In the presented single-center, prospective follow-up study, symptomatic patients with HFrEF with ID and CIEDs scheduled for IV FCM were followed up for 12-months. Arrhythmic activity was evaluated from CIEDs and non-invasive markers from Holter recordings before and after FCM.

View Article and Find Full Text PDF
Article Synopsis
  • - The study focused on understanding how pedal vessel calcification (PVC) affects the risk of major foot complications (MAFEs) and various stages of chronic kidney disease (CKD) in patients with diabetes and peripheral neuropathy.
  • - Researchers reviewed medical records of 152 patients, scoring PVC based on foot x-rays, and found that as PVC and CKD stage increased, so did the risk of experiencing any MAFE.
  • - The findings suggest that PVC could indicate a higher risk for serious foot issues and may warrant further medical attention for patients with diabetes and kidney problems.
View Article and Find Full Text PDF

Importance: Recurrence remains a challenge after ablation of outflow tract premature ventricular contractions (OT-PVCs). Although adding additional lesions next to the index effective ablation site is sometimes performed to reinforce the ablation, it remains uncertain whether this approach is effective.

Objective: To test the hypothesis that additional ablation lesions would reduce the recurrence rate compared with single-point ablation at the index effective site for the ablation of OT-PVCs.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!