Subject motion during an MRI sequence can cause ghosting effects or diffuse image noise in the phase-encoding direction and hence is likely to bias findings in neuroimaging studies. Detecting motion artifacts often relies on experts visually inspecting MRIs, which is subjective and expensive. To improve this detection, we develop a framework to automatically quantify the severity of motion artifact within a brain MRI. We formulate this task as a regression problem and train the regressor from a data set of MRIs with various amounts of motion artifacts. To resolve the issue of missing fine-grained ground-truth labels (level of artifacts), we propose Adversarial Bayesian Optimization (ABO) to infer the distribution of motion parameters (i.e., rotation and translation) underlying the acquired MRI data and then inject synthetic motion artifacts sampled from that estimated distribution into motion-free MRIs. After training the regressor on the synthetic data, we applied the model to quantify the motion level in 990 MRIs collected by the National Consortium on Alcohol and Neurodevelopment in Adolescence. Results show that the motion level derived by our approach is more reliable than the traditional metric based on Entropy Focus Criterion and manually defined binary labels.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9212065 | PMC |
http://dx.doi.org/10.1007/978-3-030-87602-9_8 | DOI Listing |
AJNR Am J Neuroradiol
January 2025
From the Orthopedic Data Innovation Lab (ODIL), Hospital for Special Surgery (A.M.L.S., M.A.F.), Department of Radiology and Imaging, Hospital for Special Surgery Centre (E.E.X, Z.I, E.T.T, D.B.S, J.L.C)and Department of Population Health Sciences, Weill Cornell Medicine (M.A.F), New York, New York, USA.
Background And Purpose: To train and evaluate an open-source generative adversarial networks (GANs) to create synthetic lumbar spine MRI STIR volumes from T1 and T2 sequences, providing a proof-of-concept that could allow for faster MRI examinations.
Materials And Methods: 1817 MRI examinations with sagittal T1, T2, and STIR sequences were accumulated and randomly divided into training, validation, and test sets. GANs were trained to create synthetic STIR volumes using the T1 and T2 volumes as inputs, optimized using the validation set, then applied to the test set.
Neuroimage
January 2025
Department of Neuroscience, The Jikei University School of Medicine, Tokyo, Japan; Human Informatics and Interaction Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Japan; Faculty of Engineering, University of Tsukuba, Tsukuba, Japan. Electronic address:
Functional MRI (fMRI) is an important tool for investigating functional networks. However, the widely used fMRI with T2*-weighted imaging in rodents has the problem of signal lack in the lateral ventral area of forebrain including the amygdala, which is essential for not only emotion but also noxious pain. Here, we scouted the zero-echo time (ZTE) sequence, which is robust to magnetic susceptibility and motion-derived artifacts, to image activation in the whole brain including the amygdala following the noxious stimulation to the hind paw.
View Article and Find Full Text PDFPhysiol Meas
January 2025
Faculty of Sciences, University of Coimbra, Palacio de las Escuelas 3004-531, Coimbra, 3004-504, PORTUGAL.
Objective: The detection of arterial pulsating signals at the skin periphery with Photoplethysmography (PPG) are easily distorted by motion artifacts. This work explores the alternatives to the aid of PPG reconstruction with movement sensors (accelerometer and/or gyroscope) which to date have demonstrated the best pulsating signal reconstruction.
Approach: A generative adversarial network with fully connected layers (FC-GAN) is proposed for the reconstruction of distorted PPG signals.
PLoS One
January 2025
Medical Image Processing Research Group (MIPRG), Dept. of Elect. & Comp. Engineering, COMSATS University Islamabad, Islamabad, Pakistan.
Recovering diagnostic-quality cardiac MR images from highly under-sampled data is a current research focus, particularly in addressing cardiac and respiratory motion. Techniques such as Compressed Sensing (CS) and Parallel Imaging (pMRI) have been proposed to accelerate MRI data acquisition and improve image quality. However, these methods have limitations in high spatial-resolution applications, often resulting in blurring or residual artifacts.
View Article and Find Full Text PDFMagn Reson Med
January 2025
Department of Radiology & Nuclear Medicine, Amsterdam University Medical Center, University of Amsterdam, Amsterdam, The Netherlands.
Purpose: To correct maternal breathing and fetal bulk motion during fetal 4D flow MRI.
Methods: A Doppler-ultrasound fetal cardiac-gated free-running 4D flow acquisition was corrected post hoc for maternal respiratory and fetal bulk motion in separate automated steps, with optional manual intervention to assess and limit fetal motion artifacts. Compressed-sensing reconstruction with a data outlier rejection algorithm was adapted from previous work.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!