Automatically Controlled Dust Generation System Using Arduino.

Sensors (Basel)

Department of Animal Science, The Pennsylvania State University, University Park, PA 16802, USA.

Published: June 2022

AI Article Synopsis

  • A dust generator was created to keep a constant level of airborne dust in a controlled chamber for studying how poultry respond to high particulate matter levels.
  • It maintained an average PM10 concentration of about 54.92 µg/m over six weeks using red oak wood dust, with a system in place to adjust for variables like humidity and blockages.
  • The setup faced challenges, such as dust clogging the recirculation filter and the exhaust fan's tendency to reduce airborne dust levels in the chamber.

Article Abstract

A dust generator was developed to disperse and maintain a desired concentration of airborne dust in a controlled environment chamber to study poultry physiological response to sustained elevated levels of particulate matter. The goal was to maintain an indicated PM10 concentration of 50 µg/m of airborne dust in a 3.7 m × 4.3 m × 2.4 m (12 ft × 14 ft × 8 ft) controlled environment chamber. The chamber had a 1.5 m/s (3200 cfm) filtered recirculation air handling system that regulated indoor temperature levels and a 0.06 m/s (130 cfm) exhaust fan that exchanged indoor air for fresh outdoor air. Dry powdered red oak wood dust that passed through an 80-mesh screen cloth was used for the experiment. The dust generator metered dust from a rectangular feed hopper with a flat bottom belt to a 0.02 m/s (46 cfm) centrifugal blower. A vibratory motor attached to the hopper ran only when the belt was operated to prevent bridging of powdered materials and to provide an even material feed rate. A laser particle counter was used to measure the concentration of airborne dust and provided feedback to an Arduino-based control system that operated the dust generator. The dust generator was operated using a duty cycle of one second on for every five seconds off to allow time for dispersed dust to mix with chamber air and reach the laser particle counter. The control system maintained an airborne PM10 dust concentration of 54.92 ± 6.42 µg/m in the controlled environment chamber during six weeks of continuous operation using red oak wood dust. An advantage of the automatically controlled dust generator was that it continued to operate to reach the setpoint concentration in response to changes in material flow due to humidity, partial blockages, and non-uniform composition of the material being dispersed. Challenges included dust being trapped by the recirculation filter and the exhaust fan removing airborne dust from the environmental chamber.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9230089PMC
http://dx.doi.org/10.3390/s22124574DOI Listing

Publication Analysis

Top Keywords

dust generator
20
dust
16
airborne dust
16
controlled environment
12
environment chamber
12
automatically controlled
8
controlled dust
8
concentration airborne
8
dust controlled
8
exhaust fan
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!