Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background and Objectives: Using an appropriate torque to tighten set screws ensures the long-term stability of spinal posterior fixation devices. However, the recommended torque often varies between different devices and some devices do not state a recommended torque level. The purpose of this study is to evaluate the effect of set screw torque on the overall construct stability and fatigue life. Materials and Methods: Two commercial pedicle screw systems with different designs for the contact interface between the set screw and rod (Group A: plane contact, Group B: line contact) were assembled using torque wrenches provided with the devices to insert the set screws and tighten to the device specifications. The axial gipping capacity and dynamic mechanical stability of each bilateral construct were assessed in accordance with ASTM F1798 and ASTM F1717. Results: Increasing or decreasing the torque on the set screw by 1 Nm from the recommended level did not have a significant effect on the axial gripping capacity or fatigue strength of Group A (p > 0.05). For Group B, over-tightening the set screw by 1 Nm did cause a significant reduction in the fatigue strength. Conclusions: Excessive torque can damage the rod surface and cause premature failure. When insertion using a manual driver is preferred, a plane contact interface between the set screw and rod can reduce damage to the rod surface when the set screw is over-torqued.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9228452 | PMC |
http://dx.doi.org/10.3390/medicina58060808 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!