A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Characterising the Features of 381 Clinical Studies Evaluating Transcutaneous Electrical Nerve Stimulation (TENS) for Pain Relief: A Secondary Analysis of the Meta-TENS Study to Improve Future Research. | LitMetric

Background and Objectives: Characterising the features of methodologies, clinical attributes and intervention protocols, of studies is valuable to advise directions for research and practice. This article reports the findings of a secondary analysis of the features from studies screened as part of a large systematic review of TENS (the meta-TENS study). Materials and Methods: A descriptive analysis was performed on information associated with methodology, sample populations and intervention protocols from 381 randomised controlled trials (24,532 participants) evaluating TENS delivered at a strong comfortable intensity at the painful site in adults with pain, irrespective of diagnosis. Results: Studies were conducted in 43 countries commonly using parallel group design (n = 334) and one comparator group (n = 231). Mean ± standard deviation (SD) study sample size (64.05 ± 58.29 participants) and TENS group size (27.67 ± 21.90 participants) were small, with only 13 of 381 studies having 100 participants or more in the TENS group. Most TENS interventions were ‘high frequency’ (>10 pps, n = 276) and using 100 Hz (109/353 reports that stated a pulse frequency value). Of 476 comparator groups, 54.2% were active treatments (i.e., analgesic medication(s), exercise, manual therapies and electrophysical agents). Of 202 placebo comparator groups, 155 used a TENS device that did not deliver currents. At least 216 of 383 study groups were able to access other treatments whilst receiving TENS. Only 136 out of 381 reports included a statement about adverse events. Conclusions: Clinical studies on TENS are dominated by small parallel group evaluations of high frequency TENS that are often contaminated by concurrent treatment(s). Study reports tended focus on physiological and clinical implications rather than the veracity of methodology and findings. Previously published criteria for designing and reporting TENS studies were neglected and this should be corrected in future research using insights gleaned from this analysis.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9230499PMC
http://dx.doi.org/10.3390/medicina58060803DOI Listing

Publication Analysis

Top Keywords

tens
11
characterising features
8
clinical studies
8
secondary analysis
8
meta-tens study
8
intervention protocols
8
parallel group
8
participants tens
8
tens group
8
comparator groups
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!