Background: Anterior cervical discectomy and interbody fusion (ACDF) may be performed with different kinds of stand-alone cages. Tantalum and polyetheretherketone (PEEK) are two of the most commonly used materials in this procedure. Few comparisons between different stand-alone implants for ACDF have been reported in the literature. Methods: We performed a comparison between patients who underwent ACDF with either a porous tantalum or a PEEK stand-alone cage, in two spine surgery units for single-level disc herniation. Clinical outcome [Neck Disability Index (NDI), Visual Analog Scale (VAS) for pain, Short Form-36 (SF-36)] and radiological outcome (lordosis, fusion and subsidence) were measured before surgery and at least one year after surgery in both groups. Results: Thirty-eight patients underwent ACDF with a porous tantalum cage, and thirty-one with a PEEK cage. The improvement of NDI and SF-36 was significantly superior in the PEEK group (p = 0.002 and p = 0.049 respectively). Moreover, the variation of the Cobb angle for the cervical spine was significantly higher in the PEEK group (p < 0.001). Conclusions: In a retrospective analysis of two groups of patients with at least one year of follow-up, a stand-alone PEEK cage showed superior clinical results, with improved cervical lordosis, compared to a stand-alone porous tantalum cage. Further studies are needed to confirm these data.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9224653PMC
http://dx.doi.org/10.3390/jpm12060986DOI Listing

Publication Analysis

Top Keywords

porous tantalum
16
anterior cervical
8
cervical discectomy
8
discectomy interbody
8
interbody fusion
8
tantalum polyetheretherketone
8
patients underwent
8
underwent acdf
8
acdf porous
8
tantalum cage
8

Similar Publications

Introduction: As the number of revision total knee arthroplasties (rTKA) continues to rise, there is increasing interest in the use of contemporary rotating hinge prostheses. These devices often incorporate porous cones to fill bone defects and enhance long-term fixation. This study evaluated the clinical and functional outcomes and survivorship in rTKA patients utilizing a rotating hinge prosthesis with flexible titanium (FT) cones, porous tantalum (PT) cones, or no cones.

View Article and Find Full Text PDF

This study investigates the deposition of tantalum (Ta) coatings on carbon foams using the chemical vapor deposition (CVD) method to enhance their compressive strength. Two types of open-cell carbon foams, CF-1 and CF-2, with different strut diameters, were examined. The morphology and uniformity of the coatings were characterized, and the effect of coating thickness on the compressive strength of the foams was systematically analyzed.

View Article and Find Full Text PDF

Bone defects are difficult to treat clinically and most often require bone grafting for repair. However, the source of autograft bone is limited, and allograft bone carries the risk of disease transmission and immune rejection. As tissue engineering technology advances, bone replacement materials are playing an increasingly important role in the treatment of bone defects.

View Article and Find Full Text PDF

Application of additive manufacturing TaBw01 porous tantalum rod in ARCO stage II osteonecrosis of the femoral head.

J Orthop Surg Res

December 2024

Center for Joint Surgery, Southwest Hospital, Army Medical University, Gaotanyan Street, Shapingba District, Chongqing, 400038, China.

Purpose: This study aims to investigate the suitable surgical strategies for applying TaBw01 porous tantalum rod across different stages of osteonecrosis of the femoral head (ONFH).

Methods: TaBw01 tantalum rods were fabricated using type FTaY-1 tantalum powder via the foam impregnation-sintering method. Mechanical testing with the Instron 8801 universal testing machine and finite element analysis (FEA) assessed single tantalum rod implantation and impaction bone grafting combined with rod implantation.

View Article and Find Full Text PDF

Anodic Oxide Films Grown in Dehydrated Phosphate/Glycerol Electrolytes at High Temperatures.

Langmuir

December 2024

Key Laboratory of Soft Chemistry and Functional Materials of Education Ministry, Nanjing University of Science and Technology, Nanjing 210094, China.

Traditional anodization was generally conducted in aqueous or water-containing solutions at room temperature or even lower temperatures. The two best known examples of the application of traditional anodization in the fabrication of nanostructured oxides are porous anodic alumina and titania nanotube films. In 1998, Melody et al.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!