Artificial intelligence (AI) models and procedures hold remarkable predictive efficiency in the medical domain through their ability to discover hidden, non-obvious clinical patterns in data. However, due to the sparsity, noise, and time-dependency of medical data, AI procedures are raising unprecedented issues related to the mismatch between doctors' mentalreasoning and the statistical answers provided by algorithms. Electronic systems can reproduce or even amplify noise hidden in the data, especially when the diagnosis of the subjects in the training data set is inaccurate or incomplete. In this paper we describe the conditions that need to be met for AI instruments to be truly useful in the orthodontic domain. We report some examples of computational procedures that are capable of extracting orthodontic knowledge through ever deeper patient representation. To have confidence in these procedures, orthodontic practitioners should recognize the benefits, shortcomings, and unintended consequences of AI models, as algorithms that learn from human decisions likewise learn mistakes and biases.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9225071PMC
http://dx.doi.org/10.3390/jpm12060957DOI Listing

Publication Analysis

Top Keywords

procedures
5
validity machine
4
machine learning
4
learning procedures
4
procedures orthodontics
4
orthodontics missing?
4
missing? artificial
4
artificial intelligence
4
intelligence models
4
models procedures
4

Similar Publications

Identifying and quantifying the dominant factors influencing heavy metal (HM) pollution sources are essential for maintaining soil ecological health and implementing effective pollution control measures. This study analyzed soil HM samples from 53 different land use types in Jiaozuo City, Henan Province, China. Pollution sources were identified using Absolute Principal Component Score (APCS), with 8 anthropogenic factors, 9 natural factors, and 4 soil physicochemical properties mapped using Geographic Information System (GIS) kernel density estimation.

View Article and Find Full Text PDF

Guidelines to minimize risk when dry needling the rectus capitus posterior major muscle.

Musculoskelet Sci Pract

January 2025

President & Chief Executive Officer Myopain Seminars, Bethesda, MD, USA; Department of Physical Therapy and Rehabilitation Science, School of Medicine, University of Maryland, Baltimore, MD, USA.

Background: Headache disorders are prevalent often leading to disability. The rectus capitus posterior major muscle (RCPMaj) may contribute to headache symptoms via nociceptive convergence and myodural bridging.

Objectives: To establish guidelines for needle length and needle angle to mitigate risks during dry needling RCPMaj.

View Article and Find Full Text PDF

Deep Equilibrium Unfolding Learning for Noise Estimation and Removal in Optical Molecular Imaging.

Comput Med Imaging Graph

January 2025

CAS Key Laboratory of Molecular Imaging, Institute of Automation, Chinese Academy of Sciences, Beijing 100190, China; School of Artificial Intelligence, University of Chinese Academy of Sciences, Beijing 100049, China; National Key Laboratory of Kidney Diseases, Beijing 100853, China. Electronic address:

In clinical optical molecular imaging, the need for real-time high frame rates and low excitation doses to ensure patient safety inherently increases susceptibility to detection noise. Faced with the challenge of image degradation caused by severe noise, image denoising is essential for mitigating the trade-off between acquisition cost and image quality. However, prevailing deep learning methods exhibit uncontrollable and suboptimal performance with limited interpretability, primarily due to neglecting underlying physical model and frequency information.

View Article and Find Full Text PDF

Feasibility of very low iodine dose aortoiliac CT angiography using dual-source photon-counting detector CT.

Eur J Radiol

January 2025

Department of Diagnostic and Interventional Radiology, Medical Center-University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany; Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, USA. Electronic address:

Purpose: To evaluate the feasibility of aortoiliac CT-Angiography (CTA) using dual-source photon-counting detector (PCD)-CT with minimal iodine dose.

Methods: This IRB-approved, single-center prospective study enrolled patients with indications for aortoiliac CTA from December 2022 to March 2023. All scans were performed using a first-generation dual-source PCD-CT.

View Article and Find Full Text PDF

Objectives: Contrast agents are frequently administered in computed tomography (CT) scans used for opportunistic screening of osteoporosis. The objective of this study is to compare the impact of contrast-related bone mineral density (BMD) increase between phantom-based and internal CT calibration techniques.

Materials And Methods: Phantom-based and internal CT calibration techniques were used to determine trabecular BMD in 93 existing clinical CT scans of the lumbar spine of 34 subjects, scanned before and after administration of contrast agents.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!