(1) Background: In brachytherapy, there are still many manual procedures that can cause adverse events which can be detected with in vivo dosimetry systems. Plastic scintillator dosimeters (PSD) have interesting properties to achieve this objective such as real-time reading, linearity, repeatability, and small size to fit inside brachytherapy catheters. The purpose of this study was to evaluate the performance of a PSD in postoperative endometrial brachytherapy in terms of source dwell time accuracy. (2) Methods: Measurements were carried out in a PMMA phantom to characterise the PSD. Patient measurements in 121 dwell positions were analysed to obtain the differences between planned and measured dwell times. (3) Results: The repeatability test showed a relative standard deviation below 1% for the measured dwell times. The relative standard deviation of the PSD sensitivity with accumulated absorbed dose was lower than 1.2%. The equipment operated linearly in total counts with respect to absorbed dose and also in count rate versus absorbed dose rate. The mean (standard deviation) of the absolute differences between planned and measured dwell times in patient treatments was 0.0 (0.2) seconds. (4) Conclusions: The PSD system is useful as a quality assurance tool for brachytherapy treatments.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9224704PMC
http://dx.doi.org/10.3390/jpm12060911DOI Listing

Publication Analysis

Top Keywords

dwell times
16
measured dwell
12
standard deviation
12
absorbed dose
12
source dwell
8
postoperative endometrial
8
differences planned
8
planned measured
8
relative standard
8
dwell
6

Similar Publications

Abnormal resting-state brain network dynamics in toddlers with autism spectrum disorder.

Eur Child Adolesc Psychiatry

January 2025

National Center for Magnetic Resonance in Wuhan, State Key Laboratory of Magnetic Resonance Spectroscopy and Imaging, Wuhan Institute of Physics and Mathematics, Innovation Academy for Precision Measurement Science and Technology, Chinese Academy of Sciences, Wuhan, 430071, China.

Emerging evidence suggests aberrant functional connectivity (FC) of brain networks in children, adolescents, and adults with autism spectrum disorder (ASD). However, little is known about alterations of dynamic FC in toddlers with ASD. The aim of this study was to investigate the characteristics of brain network dynamics in ASD toddlers.

View Article and Find Full Text PDF

Purpose: Recurrent malignant ascites is a common and challenging condition in cancer patients, often lacking a standardized treatment protocol. Small-scale studies in the literature have been insufficient to establish a treatment standard. The aim of our study was to investigate the effectiveness and safety of pigtail peritoneal catheter application in the treatment of malignant ascites.

View Article and Find Full Text PDF

Nanopore sensing is widely used for single-molecule detection, originally applied to nucleic acids and now extended to protein sensing. Our study focuses on the complex conformational changes of peptides in nanopores, which may have implications for peptide fingerprinting and protein identification. Specifically, we investigated the interaction of a β-hairpin peptide (SV28) within an α-hemolysin (αHL) nanopore.

View Article and Find Full Text PDF

Unlabelled: Corrected transposition of the great arteries (c-TGA) is a congenital abnormality characterized by atrioventricular (AV) and ventriculoarterial discordance, associated with early and late-onset conduction disturbances. We report the case of a c-TGA patient affected by congenital complete AV block, with right ventricular lead malfunction with prolonged dwell time and two abandoned leads. He underwent leadless VDD pacemaker implantation at an unusual site (i.

View Article and Find Full Text PDF

Background: Breast prosthesis infections are challenging and traditionally managed with prosthesis removal and delayed reconstruction. Single-application negative pressure wound therapy with instillation and dwell (NPWTi-d) has shown promise for salvaging infected implants, though prior studies have been small and heterogeneous. This study analyzes outcomes and compares protocols from four institutions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!