A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Integrating Distribution-Based and Anchor-Based Techniques to Identify Minimal Important Change for the Tinnitus Functional Index (TFI) Questionnaire. | LitMetric

The Tinnitus Functional Index (TFI) was developed to be responsive to small treatment-related changes in the impact of tinnitus. Yet, no studies have integrated anchor-based and distribution-based techniques to produce a single Minimal Important Change (MIC) score. Here, we evaluated the responsiveness and interpretability of the TFI, determining for the first time a robust MIC score in a UK clinical population. Two-hundred and fifty-five patients with tinnitus participated in this prospective longitudinal validation study. Distribution-based estimates (Standard Error of Measurement, Smallest Detectable Change and Effect size) and anchor-based estimates of important change (minimal clinically important difference and Receiver Operator Curve optimal value) were calculated and then integrated using a visual anchor-based MIC distribution plot. A reduction in score of -14 was determined as the MIC estimate that exceeds the measurement error, most of the variability and reliably identifies patients demonstrating true improvement. It is therefore recommended that a reduction of 14 points should be used as a minimum change required when calculating statistical power and sample size in tinnitus intervention studies and assessing patients in clinical practice.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9220811PMC
http://dx.doi.org/10.3390/brainsci12060726DOI Listing

Publication Analysis

Top Keywords

minimal change
8
tinnitus functional
8
functional tfi
8
mic score
8
change
5
tinnitus
5
integrating distribution-based
4
anchor-based
4
distribution-based anchor-based
4
anchor-based techniques
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!