(1) The malposition of the femoral tunnel in medial patellofemoral ligament (MPFL) reconstruction can lead to length changes in the MPFL graft, and an increase in medial peak pressure in the patellofemoral joint. It is the cause of 36% of all MPFL revisions. According to Schöttle et al., the creation of the drill canal should be performed in a strictly lateral radiograph. In this study, it was hypothesized that positioning the image receptor to the knee during intraoperative fluoroscopy would lead to a relevant mispositioning of the femoral tunnel, despite an always adjusted true-lateral view. (2) A total of 10 distal femurs were created from 10 knee CT scans using a 3D printer. First, true-lateral fluoroscopies were taken from lateral to medial at a 25 cm (LM25) distance from the image receptor, then from medial to lateral at a 5 cm (ML5) distance. Using the method from Schöttle, the femoral origin of the MPFL was determined when the femur was positioned distally, proximally, superiorly, and inferiorly to the image receptor. (3) The comparison of the selected MPFL insertion points according to Schöttle et al. revealed that the initial determination of the point in the ML5 view resulted in a distal and posterior shift of the point by 5.3 mm ± 1.2 mm when the point was checked in the LM25 view. In the opposite case, when the MPFL insertion was initially determined in the LM25 view and then redetermined in the ML5 view, there was a shift of 4.8 mm ± 2.2 mm anteriorly and proximally. The further positioning of the femur (distal, proximal, superior, and inferior) showed no relevant influence. (4) For fluoroscopic identification of the femoral MPFL, according to Schöttle et al., attention should be paid to the position of the fluoroscopy in addition to a true-lateral view.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9221608 | PMC |
http://dx.doi.org/10.3390/diagnostics12061427 | DOI Listing |
Orthop J Sports Med
December 2024
Department of Orthopaedics, University of Utah Health, Salt Lake City, Utah, USA.
Background: Improved patient outcomes and decreased patellar instability have been reported after medial patellofemoral ligament (MPFL) reconstruction for recurrent lateral patellar dislocation; however, there is a lack of comparative evidence on functional outcomes associated with different femoral attachment sites for the MPFL graft.
Purpose: To identify differences in MPFL reconstruction graft isometry with femoral tunnel malpositioning, specifically evaluating isometric differences as the femoral position is moved anterior, posterior, proximal, and distal relative to the Schöttle point, the femoral radiographic landmark of the MPFL.
Study Design: Descriptive laboratory study.
Z Orthop Unfall
November 2024
Orthopädie und Traumatologie, Arcus Klinik, Pforzheim, Deutschland.
Orthop J Sports Med
November 2024
Department of Trauma, Hand and Reconstructive Surgery, University Hospital Münster, Münster, Germany.
Background: Medial patellofemoral ligament (MPFL) reconstruction is a common treatment for patellar instability. Yet nearly 40% of revisions result from femoral tunnel misplacement. One reason may be the positioning of the C-arm relative to the knee.
View Article and Find Full Text PDFJ ISAKOS
October 2024
Department of Orthopedics, Unit of Musculoskeletal Surgery, Tampere University Hospital, Elämänaukio 2, 33520 Tampere, Finland; Faculty of Medicine and Health Technology Tampere University, Arvo Ylpön katu 34, 33520 Finland; Coxa Hospital for Joint Replacement, Niveltie 4, 33520 Tampere, Finland.
Arthrosc Tech
April 2024
Grupo de Joelho, Instituto de Ortopedia e Traumatologia, Hospital das Clínicas HCFMUSP, Faculdade de Medicina da Universidade de São Paulo, São Paulo, SP, Brazil.
The reconstruction of the medial patellofemoral ligament (MPFL) is an essential procedure in the surgical treatment of patellar instability. The medial third of the patellar tendon is a good graft option for this reconstruction, maintaining the insertion of the graft in the patella, with no need for hardware for patellar fixation. The objective of this article is to describe the MPFL reconstruction technique with the patellar tendon graft.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!