This discussion paper supplements our two theoretical contributions previously published in this journal on the geometric nature of visual space. We first show here how our Riemannian formulation explains the recent experimental finding (published in this special issue on size constancy) that, contrary to conclusions from past work, vergence does not affect perceived size. We then turn to afterimage experiments connected to that work. Beginning with the Taylor illusion, we explore how our proposed Riemannian visual-somatosensory-hippocampal association memory network accounts in the following way for perceptions that occur when afterimages are viewed in conjunction with body movement. The Riemannian metric incorporated in the association memory network accurately emulates the warping of 3D visual space that is intrinsically introduced by the eye. The network thus accurately anticipates the change in size of retinal images of objects with a change in Euclidean distance between the egocentre and the object. An object will only be perceived to change in size when there is a difference between the actual size of its image on the retina and the anticipated size of that image provided by the network. This provides a central mechanism for size constancy. If the retinal image is the afterimage of a body part, typically a hand, and that hand moves relative to the egocentre, the afterimage remains constant but the proprioceptive signals change to give the new hand position. When the network gives the anticipated size of the hand at its new position this no longer matches the fixed afterimage, hence a size-change illusion occurs.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9231332 | PMC |
http://dx.doi.org/10.3390/vision6020037 | DOI Listing |
Dev Biol
December 2024
Stowers Institute for Medical Research, Kansas City, MO, 64110, USA; Howard Hughes Medical Institute, Stowers Institute for Medical Research, Kansas City, MO, 64110, USA. Electronic address:
The cell nuclei of Ophisthokonts, the eukaryotic supergroup defined by fungi and metazoans, is remarkable in the constancy of their double-membraned structure in both somatic and germ cells. Such remarkable structural conservation underscores common and ancient evolutionary origins. Yet, the dynamics of disassembly and reassembly displayed by Ophisthokont nuclei vary extensively.
View Article and Find Full Text PDFVision Res
January 2025
Department of Psychology, University of Essex, Wivenhoe Park, Colchester CO4 3SQ, UK; Division of Psychology, University of Stirling, Stirling, FK9 4LA, UK. Electronic address:
Binocular disparity provides information about the depth structure of objects and surfaces in our environment. Since disparity depends on the distance to objects as well as the depth separation of points, information about distance is required to estimate depth from disparity. Our perception of size and shape is biased, such that far objects appear too small and flattened in depth, and near objects too big and stretched in depth.
View Article and Find Full Text PDFJ Med Imaging (Bellingham)
January 2025
U.S. Food & Drug Administration, Silver Spring, Maryland, United States.
J Chromatogr A
November 2024
Université de Bordeaux, INSERM U1212, UMR CNRS 5320, F-33076 Bordeaux, France.
Three-dimensional (3D) cancer models, such as multicellular tumor spheroids (MCTS), are biological supports used for research in oncology, drug development and nanotoxicity assays. However, due to various analytical and biological challenges, the main recurring problem faced when developing this type of 3D model is the lack of reproducibility. When using a 3D support to assess the effect of biologics, small molecules or nanoparticles, it is essential that the support remains constant over time and multiples productions.
View Article and Find Full Text PDFJ Appl Clin Med Phys
November 2024
SunNuclear, a Mirion Medical Company, Melbourne, Florida, USA.
Background: Quality assurance (QA) on a daily basis is an essential task in radiotherapy. In pencil beam scanning proton therapy (PBS), there is a lack of available practical QA devices for routine daily QA in comparison to conventional radiotherapy.
Purpose: The aim was to characterize and evaluate a prototype for the task of daily QA routine for PBS with parameters recommended by the AAPM TG 224, that is, the dose output constancy, the spot position and the distal range verification.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!