Two cycles of pedigree selection for grain yield/plant (GY/P) and grain weight (GW) (100-grain weight) were imposed under drought stress and normal irrigation to study the direct and indirect selection of GY/P and GW in bread wheat. The selection started in the F-generation (Cycle-C) of bread wheat ( L.) traced back to the cross () of two Egyptian cultivars. The narrow sense heritability was higher under drought than under normal irrigation and increased by selection. Under drought, the observed direct gain after two cycles of selection for GW was 21.51% ( ≤ 0.01), and accompanied with an indirect gain in GY/P of 15.52%. The observed direct gain for GY/P was 17.98% and the indirect gain in GW was 13.81%. Under normal irrigation, the observed direct gain for GW was 12.86% and the indirect gain for GY/P was 16.04%. The direct gain in GY/P was 16.04% and the indirect gain in GW was 11.95%. The genotypic correlations were different in both environments before and after selection. Single trait selection was effective in improving the selection criterion, and selection greatly affected gene associations.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9231240 | PMC |
http://dx.doi.org/10.3390/plants11121604 | DOI Listing |
Indian Pacing Electrophysiol J
January 2025
Department of Cardiovascular Medicine, Cleveland Clinic, Cleveland, OH, USA. Electronic address:
Sensors (Basel)
January 2025
Department of Agricultural Machinery Engineering, Graduate School, Chungnam National University, Daejeon 34134, Republic of Korea.
Information and communication technology (ICT) components, especially actuators in automated irrigation systems, are essential for managing precise irrigation and optimal soil moisture, enhancing orchard growth and yield. However, actuator malfunctions can lead to inefficient irrigation, resulting in water imbalances that impact crop health and reduce productivity. The objective of this study was to develop a signal processing technique to detect potential malfunctions based on the power consumption level and operating status of actuators for an automated orchard irrigation system.
View Article and Find Full Text PDFBMJ Open
January 2025
School of Nursing & Midwifery, University of Galway, Galway, Ireland.
Introduction: The peripheral vascular catheter (PVC) is the most common intravenous medical device used in hospitals, given it is crucial for the delivery of intravenous therapies. Despite its widespread use, PVC complications such as occlusion, infiltration, extravasation, phlebitis, thrombophlebitis, catheter-related thrombosis and catheter-related bloodstream infection significantly affect patient safety, leading to increased morbidity and healthcare costs. One approach to maintain PVC patency and therefore device longevity is to flush the PVC.
View Article and Find Full Text PDFJ Funct Biomater
December 2024
Department of Surgical Sciences and Integrated Diagnostics, University of Genoa, Viale Benedetto XV, 6, 16132 Genoa, Italy.
The aim of this study was to investigate the effects of retro-cavity preconditioning with or without 17% ethylenediaminetetraacetic acid (EDTA) solution on root surface pH as well as dislodgement resistance of NeoMTA2 and MTA Flow retro-fills. Forty-eight single-rooted human incisors were selected. After completion of endodontic treatment, root-end resections were performed, and retro-cavities were prepared.
View Article and Find Full Text PDFCirc Arrhythm Electrophysiol
January 2025
Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN (T.H., M.E.R., O.Y., G.N.K., N.O., T.K., L.N., D.L.P., K.C.S.).
Background: Power-controlled radiofrequency ablation with irrigated-tip catheters has been the norm for ventricular ablation for almost 2 decades. New catheter technology has recently integrated more accurate tissue temperature sensing enabling temperature-controlled irrigated ablation. We aimed to investigate the in vivo ablation parameters and lesion formation characteristics in ventricular myocardium using a novel temperature-controlled radiofrequency catheter.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!