Detection Rate and Variability in Measurement of Mandibular Incisive Canal on Cone-Beam Computed Tomography: A Study of 220 Dentate Hemi-Mandibles from Italy.

J Imaging

Department of Medical and Surgical Specialties, Radiological Sciences and Public Health, University of Brescia, ASST Spedali Civili of Brescia, Piazzale Spedali Civili, 1, I-25123 Brescia, Italy.

Published: June 2022

The mandibular incisive canal (MIC) is a small bony channel located in the interforaminal region; it represents the anterior continuation of the mandibular canal. Cone-beam computed tomography (CBCT) is the most commonly utilized radiological technique for assessing the MIC. The main purpose of this study was to evaluate the detectability and variability in measurements of the MIC on CBCT. A total of 220 dentate hemi-mandibles were retrospectively selected for this study. For each hemi-mandible, the detectability, diameter, and distance of the MIC from anatomical landmarks (cortical plates and tooth apices) were evaluated in consensus by two observers. The analysis was performed at four different levels (first premolar, canine, lateral incisor, and central incisor) and was repeated after one month. The variability of MIC measurements was expressed as the coefficient of repeatability (CR), obtained from the Bland-Altman analysis. The MIC detection rate reduced from the first premolar to the central incisor (from 82.3% to 0.5%). The CR of MIC measurements (diameter and distances from anatomical landmarks) was ≤0.74 mm. Although the MIC is difficult to detect in a non-negligible percentage of cases, the limited variability in measurements confirms that CBCT is an effective technique for the assessment of the MIC.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9225348PMC
http://dx.doi.org/10.3390/jimaging8060161DOI Listing

Publication Analysis

Top Keywords

mic
9
detection rate
8
mandibular incisive
8
incisive canal
8
canal cone-beam
8
cone-beam computed
8
computed tomography
8
220 dentate
8
dentate hemi-mandibles
8
variability measurements
8

Similar Publications

Unlabelled: Carbapenem-resistant Enterobacterales (CRE) are divided into two distinct groups: carbapenemase-producing (CPE) and non-carbapenemase-producing (non-CPE). The population of non-CPE growing on CPE selective plates during routine screening is usually not reported and is not well defined. This study aimed to characterize non-CPE isolates growing on those plates.

View Article and Find Full Text PDF

Food spoilage causes significant economic losses and endangers human health. Developing novel antimicrobial agents and preservatives is urgently needed for anti-foodborne diseases and improving food storage. Zhen Zhu Cai () species are well-known edible plants among the East Asian populace that clear heat and anti-aging.

View Article and Find Full Text PDF

A novel molecular design based on a quinazolinone scaffold was developed the attachment of aryl alkanesulfonates to the quinazolinone core through a thioacetohydrazide azomethine linker, leading to a new series of quinazolinone-alkanesulfonates 5a-r. The antimicrobial properties of the newly synthesized quinazolinone derivatives 5a-r were investigated to examine their bactericidal and fungicidal activities against bacterial pathogens like , (Gram-positive), , , (Gram-negative), in addition to (unicellular fungal). The tested compounds demonstrated reasonable bactericidal activities compared to standard drugs.

View Article and Find Full Text PDF

Microspheres based on galactomannan and Spondias purpurea L. extract to increase antifungal and antibiofilm efficacy against Candida spp.

Int J Biol Macromol

January 2025

Laboratory of Polymers and Materials Innovation, Department of Organic and Inorganic Chemistry, Sciences Center, Federal University of Ceará, Campus of Pici, Zip Code 60440-900 Fortaleza, CE, Brazil. Electronic address:

The ongoing problem of an increasing resistance of Candida spp. to available antifungals, has made it necessary the search for new therapeutic alternatives. The aim of this work was to develop a microsphere based on Caesalpinia ferrea galactomannan and Spondias purpurea L.

View Article and Find Full Text PDF

Distinguishing abiotic corrosion from two types of microbiologically influenced corrosion (MIC) using a new electrochemical biofilm/MIC test kit.

J Environ Manage

January 2025

Department of Chemical & Biomolecular Engineering, Institute for Corrosion and Multiphase Technology, Ohio University, Athens, 45701, USA; Department of Biological Sciences, Molecular & Cellular Biology Program, Ohio University, Athens, OH, 45701, USA. Electronic address:

Biofilms can cause biofouling, water quality deterioration, and transmission of infectious diseases. They are also responsible for microbiologically influenced corrosion (MIC) which can cause leaks, resulting in environmental disasters. A new disposable biofilm/MIC test kit was demonstrated to distinguish abiotic corrosion of carbon steel from MIC.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!