Routine cell culture reverse transcriptase quantitative polymerase chain reaction (RT-qPCR) gene expression analysis is limited in scalability due to minimum sample requirement and multistep isolation procedures. In this study, we aimed to optimize and apply a cost-effective and rapid protocol for directly sampling gene expression data from microplate cell cultures. The optimized protocol involves direct lysis of microplate well population followed by a reduced thermocycler reaction time one-step RT-qPCR assay. In applications for inflammation and stress-induced cell-based models, the direct lysis RT-qPCR microplate assay was utilized to detect and expression by poly(I:C) treated primary fibroblast cultures, expression by poly(I:C) iPSC-derived astrocytes, and differential expression by ER-stressed vanishing white-matter disease patient induced pluripotent stem cell (iPSC)-derived astrocytes. In application for neural differentiation medium recipe optimizations, conditions were screened for and in neuronal cultures, and , and in astrocyte cultures. The protocol provides microplate gene expression results from cell lysate to readout within ~35 min, with comparable cost to routine RT-qPCR, and it may be utilized to support laboratory cell-based assays in basic and applied scientific and medical fields of research including stem-cell differentiation, cell physiology, and drug mechanism studies.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9221485 | PMC |
http://dx.doi.org/10.3390/bios12060364 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!