Purpose: To report a successful revascularization case using the Rotarex™S atherothrombectomy system in a recent iliac limb thrombosis, and chronic hypogastric stent obstruction after previous aortoiliac aneurysm endovascular repair (EVAR).
Case Report: A 72-year-old patient was treated for recent right iliac limb thrombosis and left iliac branch chronic hypogastric stent occlusion, 5 years after EVAR. A total endovascular approach, using both upper extremity and femoral vascular access, was settled with 2 Rotarex™S (6Fr and 10Fr) devices. The Rotarex™S catheters removed most of the intraluminal material, allowing additional endografts and bare metal stents to be deployed to support a new healthy lumen surface.
Conclusion: The total endovascular approach provided by the Rotarex™S device appears to be safe and effective in treating aortoiliac endografts occlusions, both in subacute and chronic phases. Larger studies could highlight differences and eventual advantages compared with more traditional solutions.