Background And Aim: Tofacitinib is an oral small molecule Janus kinase inhibitor for the treatment of ulcerative colitis (UC). We present safety and efficacy data from patients from East Asia (Japan, Korea, and Taiwan) in OCTAVE Open, an open-label, long-term extension study.

Methods: Patients in remission at OCTAVE Open baseline received tofacitinib 5 mg twice daily (BID); all others received tofacitinib 10 mg BID. Proportions and IRs (unique patients with events/100 patient-years) were calculated for adverse events (AEs) of special interest. Efficacy endpoints were evaluated up to 36 months.

Results: In OCTAVE Open, 105/944 patients were from East Asia (tofacitinib 5 mg BID, n = 22; tofacitinib 10 mg BID, n = 83). Overall, 87.6% and 24.8% of patients had AEs and serious AEs, respectively; IRs (95% CI) for AEs of special interest were herpes zoster (HZ; non-serious and serious), 6.07 (3.40-10.02); serious infections, 1.47 (0.40-3.76); opportunistic infections, 1.91 (0.62-4.45); major cardiovascular adverse events, 0.37 (0.01-2.04); malignancies (excluding non-melanoma skin cancer [NMSC]), 0.37 (0.01-2.04); and NMSC, 0.00 (0.00-1.35). No deaths, venous thromboembolic events, or gastrointestinal perforations occurred. At month 36, 68.2% and 54.2% of patients had a clinical response, 68.2% and 53.0% had endoscopic improvement, and 63.6% and 49.4% were in remission with tofacitinib 5 and 10 mg BID, respectively.

Conclusions: The HZ IR in East Asian patients was numerically higher versus the global study population; excluding HZ, tofacitinib safety and efficacy were consistent with the global study population.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9796539PMC
http://dx.doi.org/10.1111/jgh.15923DOI Listing

Publication Analysis

Top Keywords

octave open
16
safety efficacy
12
tofacitinib 10 mg
12
10 mg bid
12
tofacitinib
8
east asian
8
patients
8
asian patients
8
ulcerative colitis
8
patients east
8

Similar Publications

Transient acoustic holography is a useful technique for characterization of ultrasound transducers. It involves hydrophone measurements of the 2-D distribution of acoustic pressure waveforms in a transverse plane in front of the transducer - a hologram - and subsequent numerical forward or backward projection of the ultrasound field. This approach enables full spatiotemporal reconstruction of the acoustic field, including the vibrational velocity at the transducer surface.

View Article and Find Full Text PDF

Introduction: Survival from ovarian cancer in the UK is poor compared with international comparators. The Ovarian Cancer Audit Feasibility Pilot demonstrated variation in 1-year and 5-year survival across the UK as well as significant variation in treatment rates. In 2020, IMPROVE-UK was established as the first major programme to address inequalities in ovarian cancer management and survival across the UK, to develop a legacy of best practice sharing across the country and to establish and evaluate quality improvement projects that could drive care at scale.

View Article and Find Full Text PDF

Background: In relapsing-remitting multiple sclerosis (RRMS), extended exposure to high-efficacy disease modifying therapy may increase the risk of side effects, compromise treatment adherence, and inflate medical costs. Treatment de-escalation, here defined as a switch to a lower efficacy therapy, is often considered by patients and physicians, but evidence to guide such decisions is scarce. In this study, we aimed to compare clinical outcomes between patients who de-escalated therapy versus those who continued their therapy.

View Article and Find Full Text PDF

Nanoscale thickness Octave-spanning coherent supercontinuum light generation.

Light Sci Appl

January 2025

Department of Electronics and Nanoengineering, Aalto University, Espoo, Finland.

Coherent broadband light generation has attracted massive attention due to its numerous applications ranging from metrology, sensing, and imaging to communication. In general, spectral broadening is realized via third-order and higher-order nonlinear optical processes (e.g.

View Article and Find Full Text PDF

Objective: To evaluate a novel user-operated audiometry method allowing users full control in determining their pure-tone hearing thresholds.

Design: Comparative study. Participants were recruited from a hearing clinic after undergoing manual audiometry (six frequencies).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!