Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9207727PMC
http://dx.doi.org/10.1016/j.hroo.2022.04.002DOI Listing

Publication Analysis

Top Keywords

implantable cardiac
4
cardiac monitors
4
monitors cryptogenic
4
cryptogenic stoke
4
stoke clarity
4
clarity uncertainty?
4
implantable
1
monitors
1
cryptogenic
1
stoke
1

Similar Publications

Percutaneous valve implantation or surgical replacement with mechanical or biological valves are standard therapies for severe valvular heart diseases. Prosthetic valve thrombosis, though rare, is a serious complication, particularly with mechanical prostheses. This study aimed to investigate the predictive value of platelet volume parameters, including mean platelet volume (MPV), platelet distribution width (PDW), and platelet-large cell ratio (P-LCR), for valvular thrombosis risk in patients undergoing valve replacement therapy.

View Article and Find Full Text PDF

Background: Patient-specific, 3-dimensional printed, tissue engineered vascular grafts (3DTEVGs) are manufactured to optimize hemodynamic performance and to accommodate growth. We evaluate growth outcomes of 3DTEVGs compared with standard grafts for pulmonary artery reconstruction in porcine models.

Methods: Magnetic resonance imaging (MRI) with 4-dimensional flow data was acquired in porcine models (n = 8).

View Article and Find Full Text PDF

Background: The objective of this study was to report the 5-year outcomes of hybrid arch frozen elephant trunk (FET) procedures with a multibranched hybrid graft.

Methods: Between 2014 and 2020, 50 consecutive patients (63 ± 15 years old; 34% women) underwent hybrid arch FET with Thoraflex hybrid graft (Terumo Aortic) at a single center. Indications included aortic aneurysm (n = 48 [96%]), acute aortic dissection (n = 10 [20%]), and chronic dissection (n = 20 [40%]).

View Article and Find Full Text PDF

A 67-year-old man with medical history of ischemic cardiomyopathy with stage D heart failure and infrarenal abdominal aortic aneurysm underwent implantation of a left ventricular assist device (LVAD). Three months after the procedure, he presented with unrelenting back pain and a rapidly increased in size aneurysm. The patient underwent urgent endovascular aneurysm repair with uncomplicated recovery.

View Article and Find Full Text PDF

A 44-year-old man with a history of facioscapulohumeral muscular dystrophy and pectus excavatum presented with multiyear history of progressive, severe respiratory dysfunction, pain, recurrent respiratory infection, and chest wall deformity. With bioprosthetic engineers, the surgical team customized a 3-dimensional printed model of a sternal implant interacting with the patient's anatomy. After approval from the Food and Drug Administration, the customized sternal plates were created and implanted in a sternal reconstruction operation.

View Article and Find Full Text PDF