Quantification of respiratory sounds by a continuous monitoring system can be used to predict complications after extubation: a pilot study.

J Clin Monit Comput

Department of Emergency and Critical Care Medicine, Graduate School of Biomedical and Health Sciences, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima, 734-8551, Japan.

Published: February 2023

To show that quantification of abnormal respiratory sounds by our developed device is useful for predicting respiratory failure and airway problems after extubation. A respiratory sound monitoring system was used to collect respiratory sounds in patients undergoing extubation. The recorded respiratory sounds were subsequently analyzed. We defined the composite poor outcome as requiring any of following medical interventions within 48 h as defined below. This composite outcome includes reintubation, surgical airway management, insertion of airway devices, unscheduled use of noninvasive ventilation or high-flow nasal cannula, unscheduled use of inhaled medications, suctioning of sputum by bronchoscopy and unscheduled imaging studies. The quantitative values (QV) for each abnormal respiratory sound and inspiratory sound volume were compared between composite outcome groups and non-outcome groups. Fifty-seven patients were included in this study. The composite outcome occurred in 18 patients. For neck sounds, the QVs of stridor and rhonchi were significantly higher in the outcome group vs the non-outcome group. For anterior thoracic sounds, the QVs of wheezes, rhonchi, and coarse crackles were significantly higher in the outcome group vs the non-outcome group. For bilateral lateral thoracic sounds, the QV of fine crackles was significantly higher in the outcome group vs the non-outcome group. Cervical inspiratory sounds volume (average of five breaths) immediately after extubation was significantly louder in the outcome group vs non-outcome group (63.3 dB vs 54.3 dB, respectively; p < 0.001). Quantification of abnormal respiratory sounds and respiratory volume may predict respiratory failure and airway problems after extubation.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10877-022-00884-4DOI Listing

Publication Analysis

Top Keywords

respiratory sounds
16
outcome group
16
group non-outcome
16
non-outcome group
16
composite outcome
12
higher outcome
12
sounds
8
monitoring system
8
abnormal respiratory
8
respiratory sound
8

Similar Publications

Corrigendum: Abnormal respiratory sounds classification using deep CNN through artificial noise addition.

Front Med (Lausanne)

January 2025

Department of Computer and Network Engineering, College of Information Technology, UAE University, Al Ain, United Arab Emirates.

[This corrects the article DOI: 10.3389/fmed.2021.

View Article and Find Full Text PDF

Ethnopharmacological Relevance: Xiao'er Feike Granules (XFG) is an approved and widely used classical Chinese medicine prescription for the treatment of pediatric respiratory diseases. Extensive clinical studies have reported that XFG demonstrates high efficacy and minimal adverse reactions in treating acute bronchitis (AB). However, there is an urgent need for a more cohesive evaluation of the evidence regarding the safe clinical use of XFG for AB.

View Article and Find Full Text PDF

Comparison of the Effect of the White Noise and Sound Reduction on Behavioral Responses of Premature Infants Under Noninvasive Ventilation: A Clinical Trial.

J Perinat Neonatal Nurs

January 2025

Author Affiliations: Department of Pediatric and Neonatal Nursing, School of Nursing and Midwifery, Mashhad University of Medical Sciences, Mashhad, Iran (Mrs Mohseni and Dr Ramezani); Nursing and Midwifery Care Research Center, Mashhad University of Medical Sciences, Mashhad, Iran Mrs (Dr Ramezani); Department of Epidemiology and Biostatistics, School of Health, Mashhad University of Medical Sciences, Mashhad, Iran (Dr Saki); and Neonatologist, NICU Department, Hakim Hospital, Neyshabur University of Medical Sciences, Neyshabur, Iran (Dr Poor-Alizadeh).

With the increasing survival rates of premature infants and their associated respiratory problems, noninvasive ventilation has gained popularity in neonatal intensive care units. On the other hand, this equipment can be stressful for infants. Objective: This study aimed to compare the effects of white noise and sound reduction on the behavioral responses of premature infants under noninvasive ventilation.

View Article and Find Full Text PDF

Introduction: The study was conducted to observe the effect of using relaxing sounds as a nonpharmacological intervention on anxiety levels and vital signs among patients who underwent extraction.

Materials And Methods: A randomized clinical trial was conducted, and patients with an indication of dental extraction, who were physically and mentally healthy, were invited to voluntarily participate in the study. Dental anxiety was assessed by measuring blood pressure, heart rates, and respiratory rates as well as with the help of the Modified Dental Anxiety Scale (MDAS) questionnaire before and after the procedure.

View Article and Find Full Text PDF

Background: Foreign body inhalation is rare in older children, often leading to underdiagnosis and delayed treatment. Most cases involve a single foreign body, but instances of multiple foreign bodies are exceedingly uncommon. This report presents a case of an elder child who inhaled two pen caps, emphasizing the need for clinical vigilance and thorough medical history collection.

View Article and Find Full Text PDF