Purpose: To evaluate the trueness of one stationary and two mobile systems for 3D facial scanning.
Materials And Methods: Twenty participants were included in this study. After marking facial soft tissue landmarks, their faces were scanned using three facial scanning systems: the Bellus3D Dental Pro app on an iPad Pro 2020 (Apple; IP); the ARC-7 Face Scanning System (Bellus3D; BA); and the EinScan Pro 2X Plus (Shining 3D Tech; EP) following the manufacturers' operating instructions. Three-dimensional images were reconstructed with corresponding software and saved in object (OBJ) file format. The interlandmark distances were measured and compared to direct caliper measurements, and absolute error (AE) was chosen as the measurement to determine the trueness of the three scanners. The normal distribution and variance of homogeneity were measured, and then the data were analyzed using one-way ANOVA or Kruskal-Wallis H test. The significance level was set at P = .05.
Results: For the measurement of interlandmark distances, no significant differences were found among the four measuring techniques, and the mean AEs of the IP, BA, and EP systems were 1.17 ± 0.80 mm, 0.76 ± 0.61 mm, and 0.69 ± 0.65 mm.
Conclusion: The three facial scanning systems tested provided a reliable 3D facial reconstruction. The portable IP system could meet the clinical requirements for facial scanning, but it is suggested to select the EP and BA systems when a higher trueness is required.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.11607/ijp.7746 | DOI Listing |
ANZ J Surg
December 2024
Royal Prince Alfred Institute of Academic Surgery, Sydney Local Health District, Sydney, New South Wales, Australia.
Background: Facial prosthetics are an important means to rehabilitate patients with congenital or acquired facial defects. However, with a time-consuming manual workflow and workforce shortage, access to facial prosthetics is limited in Australia and worldwide, especially for rural and remote patients. Optical 3D scanning has been increasingly integrated in digitizing data.
View Article and Find Full Text PDFMicrocirculation
January 2025
Eye Research Center, The Five Senses Health Institute, Moheb Kowsar Hospital, School of Medicine, Iran University of Medical Sciences, Tehran, Iran.
Purpose: To assess the colocalization of ellipsoid zone (EZ) disruption with nonperfusion in choriocapillaris (CC), retinal superficial capillary plexus (SCP), and deep capillary plexus (DCP) in diabetic patients using en face optical coherence tomography (OCT) and OCT angiography (OCTA).
Methods: Macular OCT and OCTA scans (3 × 3 mm) of 41 patients with diabetic retinopathy were obtained using an RTVue XR Avanti instrument. After correcting the shadow artifacts, EZ integrity was assessed in the en face OCT slab using the Gaussian mixture model clustering method compared with the corresponding EZ en face OCT of 11 age-matched normal patients.
Ecotoxicol Environ Saf
December 2024
Hebei University of Science and Technology, 050018, China. Electronic address:
Polylactic acid (PLA) composites with high straw content face several challenges, primarily due to the inherent brittleness of straw and its poor compatibility with the polymer matrix. In this study, scanning electron microscopy (SEM) was used to analyze the microscopic structure of wheat straw chemically modified by NaOH and the silane coupling agent, and it was concluded that both treatments effectively removed waxes and silica from the surface of the straw, enhanced fiber roughness, and improved interfacial adhesion. Notably, the silane coupling agent treatment not only facilitated the formation of chemical bonds between the straw fibers and the PLA matrix but also filled the interfiber pores, significantly increasing the structural density.
View Article and Find Full Text PDFJ Craniofac Surg
December 2024
Department of Medical Cosmetology, Chengdu Second People's Hospital, Chengdu, Sichuan, China.
Background: Among several skin fillers developed in recent decades, hyaluronic acid (HA) is a widely used filler for face contouring and is generally believed to be safe, long-lasting, not immunogenic, and cost-effective. However, early and delayed complications can also occur following HA filler injection. Unfortunately, there have been reports of HA-related bone erosion in the chin area without clear scientific data regarding its existence and incidence.
View Article and Find Full Text PDFJ Imaging
December 2024
European Commission, Joint Research Centre (JRC), Via Enrico Fermi 2749, 21027 Ispra, Italy.
In this paper, we face the point-cloud segmentation problem for spinning laser sensors from a deep-learning (DL) perspective. Since the sensors natively provide their measurements in a 2D grid, we directly use state-of-the-art models designed for visual information for the segmentation task and then exploit the range information to ensure 3D accuracy. This allows us to effectively address the main challenges of applying DL techniques to point clouds, i.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!