A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Long-Term Clinical Outcomes and Implant Survivorship of 151 Total Ankle Arthroplasties Using the HINTEGRA Prosthesis: A Minimum 10-Year Follow-up. | LitMetric

Background: Few studies have investigated long-term clinical outcomes of a mobile-bearing total ankle arthroplasty (TAA) system. This study analyzed long-term outcomes of TAA using the HINTEGRA prosthesis at a single, non-developer center.

Methods: Primary TAAs were performed on 213 ankles in 194 patients, and 151 consecutive ankles [71%] in 136 patients with a minimum follow-up of 10 years after the primary TAA were included in this study. Clinical results were assessed using a visual analog scale (VAS) pain score, the American Orthopaedic Foot & Ankle Society (AOFAS) Ankle-Hindfoot Scale score, the Ankle Osteoarthritis Scale (AOS) pain and disability subscores, and ankle range of motion. Prosthesis survivorship, reoperations, and risk factors were also evaluated.

Results: The mean follow-up was 135.5 months (range, 120.0 to 204.0 months). All clinical scores and ankle range of motion improved significantly from preoperatively to 2 years, 4 to 6 years, and ≥10 years after TAA (p < 0.001). A total of 43 ankles (28.5%) required revision procedures, with the most common reason being periprosthetic osteolysis (32 ankles [21.2%]). The overall implant survivorship was 93.5% in Kaplan-Meier survival analysis at the mean follow-up of 11.3 years after the TAA.

Conclusions: TAA using the HINTEGRA prosthesis with careful follow-up observation and appropriate adjunct procedures for the treatment of end-stage ankle arthritis produced satisfactory clinical results, which were maintained at a follow-up of ≥10 years, and resulted in 93.5% of implant survivorship.

Level Of Evidence: Prognostic Level IV . See Instructions for Authors for a complete description of levels of evidence.

Download full-text PDF

Source
http://dx.doi.org/10.2106/JBJS.22.00060DOI Listing

Publication Analysis

Top Keywords

hintegra prosthesis
12
long-term clinical
8
clinical outcomes
8
implant survivorship
8
total ankle
8
taa hintegra
8
ankle range
8
range motion
8
≥10 years
8
ankle
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!