Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Few studies have investigated long-term clinical outcomes of a mobile-bearing total ankle arthroplasty (TAA) system. This study analyzed long-term outcomes of TAA using the HINTEGRA prosthesis at a single, non-developer center.
Methods: Primary TAAs were performed on 213 ankles in 194 patients, and 151 consecutive ankles [71%] in 136 patients with a minimum follow-up of 10 years after the primary TAA were included in this study. Clinical results were assessed using a visual analog scale (VAS) pain score, the American Orthopaedic Foot & Ankle Society (AOFAS) Ankle-Hindfoot Scale score, the Ankle Osteoarthritis Scale (AOS) pain and disability subscores, and ankle range of motion. Prosthesis survivorship, reoperations, and risk factors were also evaluated.
Results: The mean follow-up was 135.5 months (range, 120.0 to 204.0 months). All clinical scores and ankle range of motion improved significantly from preoperatively to 2 years, 4 to 6 years, and ≥10 years after TAA (p < 0.001). A total of 43 ankles (28.5%) required revision procedures, with the most common reason being periprosthetic osteolysis (32 ankles [21.2%]). The overall implant survivorship was 93.5% in Kaplan-Meier survival analysis at the mean follow-up of 11.3 years after the TAA.
Conclusions: TAA using the HINTEGRA prosthesis with careful follow-up observation and appropriate adjunct procedures for the treatment of end-stage ankle arthritis produced satisfactory clinical results, which were maintained at a follow-up of ≥10 years, and resulted in 93.5% of implant survivorship.
Level Of Evidence: Prognostic Level IV . See Instructions for Authors for a complete description of levels of evidence.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.2106/JBJS.22.00060 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!