Tandem mass tags (TMTs) enable simple and accurate quantitative proteomics for multiplexed samples by relative quantification of tag reporter ions. Orbitrap quantification of reporter ions has been associated with a characteristic notch region in intensity distribution, within which few reporter intensities are recorded. This has been resolved in version 3 of the instrument acquisition software Tune. However, 47% of Orbitrap Fusion, Lumos, or Eclipse submissions to PRIDE were generated using prior software versions. To quantify the impact of the notch on existing quantitative proteomics data, we generated a mixed species benchmark and acquired quantitative data using Tune versions 2 and 3. Intensities below the notch are predominantly underestimated with Tune version 2, leading to overestimation of the true differences in intensities between samples. However, when summarizing reporter ion intensities to higher-level features, such as peptides and proteins, few features are significantly affected. Targeted removal of spectra with reporter ion intensities below the notch is not beneficial for differential peptide or protein testing. Overall, we find that the systematic quantification bias associated with the notch is not detrimental for a typical proteomics experiment.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9204819PMC
http://dx.doi.org/10.1021/acsmeasuresciau.1c00053DOI Listing

Publication Analysis

Top Keywords

acquisition software
8
software versions
8
quantitative proteomics
8
reporter ions
8
intensities notch
8
reporter ion
8
ion intensities
8
intensities
6
reporter
5
notch
5

Similar Publications

Nexus: A versatile console for advanced low-field MRI.

Magn Reson Med

January 2025

Department 8.1 - Biomedical Magnetic Resonance, Physikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Germany.

Purpose: To develop a low-cost, high-performance, versatile, open-source console for low-field MRI applications that can integrate a multitude of different auxiliary sensors.

Methods: A new MR console was realized with four transmission and eight reception channels. The interface cards for signal transmission and reception are installed in PCI Express slots, allowing console integration in a commercial PC rack.

View Article and Find Full Text PDF

Evaluation of charge summing correction in CdTe-based photon-counting detectors for breast CT: performance metrics and image quality.

J Med Imaging (Bellingham)

January 2025

U.S. Food and Drug Administration, Office of Science and Engineering Labs, Division of Imaging, Diagnostics, and Software Reliability, Silver Spring, Maryland, United States.

Purpose: We evaluate the impact of charge summing correction on a cadmium telluride (CdTe)-based photon-counting detector in breast computed tomography (CT).

Approach: We employ a custom-built laboratory benchtop system using the X-THOR FX30 0.75-mm CdTe detector (Varex Imaging, Salt Lake City, Utah, United States) with a pixel pitch of 0.

View Article and Find Full Text PDF

Exploring the optimal reconstruction strategy for Enneking III defects in pelvis bone tumors: a finite element analysis.

J Orthop Surg Res

January 2025

Department of Orthopedic Surgery, Shanghai Tenth People's Hospital, Tongji University School of Medicine, 301 Yanchang Middle Road, Shanghai, 200072, People's Republic of China.

Background: Controversy exists regarding the reconstruction of bone defects in Enneking III. This study aimed to use the finite element analysis (FEA) method to clarify (1) the utility of reconstructing the pelvis Enneking III region and (2) the optimal approach for this reconstruction.

Methods: FEA models were generated for three types of Enneking III defects in the pelvis, replacing all the defect areas in region III with a sizable solid box for topology optimization (TO).

View Article and Find Full Text PDF

Background: Computed tomography scans are widely used in everyday medical practice due to speed, image reliability, and detectability of a wide range of pathologies. Each scan exposes the patient to a radiation dose, and performing a fast estimation of the effective dose (E) is an important step for radiological safety. The aim of this work is to estimate E from patient and CT acquisition parameters in the absence of a dose-tracking software exploiting machine learning.

View Article and Find Full Text PDF

The coronavirus disease 2019 (COVID-19) pandemic disrupted conventional teaching methodologies, forcing educational institutions to swiftly adapt to remote learning. This study aimed to compare the effectiveness of video- and powerpoint-based teaching methods in the knowledge of medical students using a systematic review and meta-analysis. A systematic review of the literature was conducted to identify relevant studies that compared the efficacy of video-based and PowerPoint-based teaching methods in medical students during the COVID-19 pandemic.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!