Purpose: Although both relaxation and diffusion imaging are sensitive to tissue microstructure, studies have reported limited sensitivity and robustness of using relaxation or conventional diffusion alone to characterize tissue microstructure. Recently, it has been shown that tensor-valued diffusion encoding and joint relaxation-diffusion quantification enable more reliable quantification of compartment-specific microstructural properties. However, scan times to acquire such data can be prohibitive. Here, we aim to simultaneously quantify relaxation and diffusion using MR fingerprinting (MRF) and b-tensor encoding in a clinically feasible time.
Methods: We developed multidimensional MRF scans (mdMRF) with linear and spherical b-tensor encoding (LTE and STE) to simultaneously quantify T1, T2, and ADC maps from a single scan. The image quality, accuracy, and scan efficiency were compared between the mdMRF using LTE and STE. Moreover, we investigated the robustness of different sequence designs to signal errors and their impact on the maps.
Results: T1 and T2 maps derived from the mdMRF scans have consistently high image quality, while ADC maps are sensitive to different sequence designs. Notably, the fast imaging steady state precession (FISP)-based mdMRF scan with peripheral pulse gating provides the best ADC maps that are free of image distortion and shading artifacts.
Conclusion: We demonstrated the feasibility of quantifying T1, T2, and ADC maps simultaneously from a single mdMRF scan in around 24 s/slice. The map quality and quantitative values are consistent with the reference scans.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9420788 | PMC |
http://dx.doi.org/10.1002/mrm.29352 | DOI Listing |
Invest Radiol
January 2025
From the Department of Radiology, Stanford University, Stanford, CA (K.W., M.J.M., A.M.L., A.B.S., A.J.H., D.B.E., R.L.B.); Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, CA (K.W.); GE HealthCare, Houston, TX (X.W.); GE HealthCare, Boston, MA (A.G.); and GE HealthCare, Menlo Park, CA (P.L.).
Objectives: Pancreatic diffusion-weighted imaging (DWI) has numerous clinical applications, but conventional single-shot methods suffer from off resonance-induced artifacts like distortion and blurring while cardiovascular motion-induced phase inconsistency leads to quantitative errors and signal loss, limiting its utility. Multishot DWI (msDWI) offers reduced image distortion and blurring relative to single-shot methods but increases sensitivity to motion artifacts. Motion-compensated diffusion-encoding gradients (MCGs) reduce motion artifacts and could improve motion robustness of msDWI but come with the cost of extended echo time, further reducing signal.
View Article and Find Full Text PDFRadiol Artif Intell
January 2025
From the Department of Radiation Oncology (A.S.G., V.H., H.S.) and Department of Radiology and Imaging Sciences (B.D.W.), Emory University School of Medicine, 1701 Uppergate Dr, C5008 Winship Cancer Institute, Atlanta, GA 30322; Department of Radiology, University of Miami {School of Medicine?}, Miami, Fla (S.S., A.A.M.); Department of {Radiology?} Northwestern University {Feinberg School of Medicine?}, Chicago, Ill (L.A.D.C.); Department of Biostatistics and Bioinformatics, Emory University Rollins School of Public Health, Atlanta, Ga (Y.L.); Department of Psychology, Emory University, Atlanta, Ga (M.T.); and Department of Radiology, Duke University Medical Center, Durham, NC (B.J.S.).
Purpose To develop and evaluate the performance of NNFit, a self-supervised deep-learning method for quantification of high-resolution short echo-time (TE) echo-planar spectroscopic imaging (EPSI) datasets, with the goal of addressing the computational bottleneck of conventional spectral quantification methods in the clinical workflow. Materials and Methods This retrospective study included 89 short-TE whole-brain EPSI/GRAPPA scans from clinical trials for glioblastoma (Trial 1, May 2014-October 2018) and major-depressive-disorder (Trial 2, 2022- 2023). The training dataset included 685k spectra from 20 participants (60 scans) in Trial 1.
View Article and Find Full Text PDFCureus
December 2024
Department of Radiology, University of Medicine and Pharmacy of Craiova, Craiova, ROU.
Background: Cervical cancer is considered one of the most common gynecological malignancies with an increased incidence in developing countries. Magnetic resonance imaging (MRI) plays a valuable role in staging cervical cancer and providing valuable information necessary for selecting the appropriate treatment plan, while closely correlating with the prognosis of the patient.
Objective: The aim of this study is to assess the diagnostic value of diffusion-weighted imaging (DWI) in the preoperative loco-regional staging of cervical carcinoma.
Curr Med Imaging
January 2025
Department of Radiology and Medical Imaging, King Saud University Medical City, King Saud University, Riyadh, KSA.
Background: Multiple sclerosis (MS) is one of the most common disabling central nervous system diseases affecting young adults. Magnetic resonance imaging (MRI) is an essential tool for diagnosing and following up multiple sclerosis. Over the years, many MRI techniques have been developed to improve the sensitivity of MS disease detection.
View Article and Find Full Text PDFCancers (Basel)
December 2024
Department of Diagnostic and Interventional Radiology, University Hospital Split, Spinčićeva 1, 21000 Split, Croatia.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!