A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Dye removal with emulsion liquid membrane: experimental design and response surface methodology. | LitMetric

This work aims to removing anionic food dyes, Acid Red18 (E124) and Quinoline Yellow WS (E104), from their aqueous solutions. The Emulsion Liquid Membrane (ELM) technique was used. ELM consists of diluent (kerosene), nonionic surfactant (0.5 wt. % Triton X-45), Aliquat 336 as an extractant. Sulfuric acid (HSO) solution was used as an internal aqueous phase. The key parameters impacting the stability of liquid membrane and the efficiency of dye removal were investigated; Almost 98% of E124 at 50 mg/L are successfully extracted under optimum conditions. The extraction of a mixture of the two dyes at equal concentrations (25 mg/L) was conducted and their extraction showed more than 95% of efficiency. The experimental results of dye mixture (E124, E104) extraction were expressed by the following three quantities: The concentration of Triton X-45, the concentration of Aliquat 336, and the internal phase concentration of HSO represented on three dimensional plots using the Box-Behnken design and the response surface methodology. For each of the parameters, the values of which were determined by experimental design, these results were subjected to empirical smoothing. The values, thus calculated, are consistent with the measurements.

Download full-text PDF

Source
http://dx.doi.org/10.1080/09593330.2022.2091480DOI Listing

Publication Analysis

Top Keywords

liquid membrane
12
dye removal
8
emulsion liquid
8
experimental design
8
design response
8
response surface
8
surface methodology
8
triton x-45
8
aliquat 336
8
removal emulsion
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!