The aim of this study is to investigate the incidental prostate cancer (iPCa) detection rates of different embedding methods in a large, contemporary cohort of patients with bladder outlet obstruction (BOO) treated with transurethral surgery. We relied on an institutional tertiary-care database to identify BOO patients who underwent either transurethral loop resection or laser (Holmium:yttrium-aluminium garnet) enucleation of the prostate (HoLEP) between 01/2012 and 12/2019. Embedding methods differed with regard to the extent of the additional prostate tissue submitted following the first ten cassettes of primary embedding (cohort A: one [additional] cassette/10 g residual tissue vs. cohort B: complete embedding of the residual tissue). Detection rates of iPCa among the different embedding methods were compared. Subsequently, subgroup analyses by embedding protocol were repeated in HoLEP-treated patients only. In the overall cohort, the iPCa detection rate was 11% (46/420). In cohort A (n = 299), tissue embedding resulted in a median of 8 cassettes/patient (range 1-38) vs. a median of 15 (range 2-74) in cohort B (n = 121) (p < .001). The iPCa detection rate was 8% (23/299) and 19% (23/121) in cohort A vs. cohort B, respectively (p < .001). Virtual reduction of the number of tissue cassettes to ten cassettes resulted in a iPCa detection rate of 96% in both cohorts, missing one stage T1a/ISUP grade 1 carcinoma. Increasing the number of cassettes by two and eight cassettes, respectively, resulted in a detection rate of 100% in both cohorts without revealing high-grade carcinomas. Subgroup analyses in HoLEP patients confirmed these findings, demonstrated by a 100 vs. 96% iPCa detection rate following examination of the first ten cassettes, missing one case of T1a/ISUP 1. Examination of 8 additional cassettes resulted in a 100% detection rate. The extent of embedding of material obtained from transurethral prostate resection correlates with the iPCa detection rate. However, the submission of 10 cassettes appears to be a reasonable threshold to reduce resource utilization while maintaining secure cancer detection.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9485088PMC
http://dx.doi.org/10.1007/s00428-022-03331-6DOI Listing

Publication Analysis

Top Keywords

embedding methods
12
embedding
8
tissue embedding
8
incidental prostate
8
ipca detection
8
detection rates
8
residual tissue
8
cohort
6
tissue
5
prostate
5

Similar Publications

Objective: To compare fall risk scores of hearing aids embedded with inertial measurement units (IMU-HAs) and powered by artificial intelligence (AI) algorithms with scores by trained observers.

Study Design: Prospective, double-blinded, observational study of fall risk scores between trained observers and those of IMU-HAs.

Setting: Tertiary referral center.

View Article and Find Full Text PDF

FRESH extrusion 3D printing of type-1 collagen hydrogels photocrosslinked using ruthenium.

PLoS One

January 2025

The Henry M. Jackson Foundation for the Advancement of Military Medicine, Inc., Bethesda, Maryland, United States of America.

The extrusion bioprinting of collagen material has many applications relevant to tissue engineering and regenerative medicine. Freeform Reversible Embedding of Suspended Hydrogels (FRESH) technology is capable of 3D printing collagen material with the specifications and details needed for precise tissue guidance, a crucial requirement for effective tissue repair. While FRESH has shown repeated success and reliability for extrusion printing, the mechanical properties of completed collagen prints can be improved further by post-print crosslinking methodologies.

View Article and Find Full Text PDF

The topology of a chaotic attractor in the Kuramoto-Sivashinsky equation.

Chaos

January 2025

Emergent Complexity in Physical Systems Laboratory (ECPS), École Polytechnique Fédérale de Lausanne, 1015 Lausanne, Switzerland.

The Birman-Williams theorem gives a connection between the collection of unstable periodic orbits (UPOs) contained within a chaotic attractor and the topology of that attractor, for three-dimensional systems. In certain cases, the fractal dimension of a chaotic attractor in a partial differential equation (PDE) is less than three, even though that attractor is embedded within an infinite-dimensional space. Here, we study the Kuramoto-Sivashinsky PDE at the onset of chaos.

View Article and Find Full Text PDF

Embedding techniques allow the efficient description of correlations within localized fragments of large molecular systems while accounting for their environment at a lower level of theory. We introduce FragPT2: a novel embedding framework that addresses multiple interacting active fragments. Fragments are assigned separate active spaces, constructed by localizing canonical molecular orbitals.

View Article and Find Full Text PDF

Purpose: The double-flap technique (DFT) is an anti-reflux reconstruction procedure performed after proximal gastrectomy (PG), but its complexity and high incidence of anastomotic stenosis are problematic. We conducted this study to demonstrate the efficacy of robot-assisted DFT, with refinements, to address these issues.

Methods: Surgical outcomes were compared between the following procedures modified over time at our institution: conventional open DFT (group O, n = 16); early robotic DFT (group RE, n = 19), which follows the conventional open PG approach; and late robotic DFT (group RL, n = 21), which incorporates refinements to the early robotic DFT technique by exploiting more of the robotic capabilities available.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!