Impact of ethnicity on the accuracy of measurements of oxygen saturations: A retrospective observational cohort study.

EClinicalMedicine

Birmingham Acute Care Research Group, Institute of Inflammation and Ageing, New Queen Elizabeth Hospital, University of Birmingham, 1st Floor, Mindelsohn Way, Birmingham B15 2WB, United Kingdom.

Published: June 2022

Background: Pulse oximeters are routinely used in community and hospital settings worldwide as a rapid, non-invasive, and readily available bedside tool to approximate blood oxygenation. Potential racial biases in peripheral oxygen saturation (SpO2) measurements may influence the accuracy of pulse oximetry readings and impact clinical decision making. We aimed to assess whether the accuracy of oxygen saturation measured by SpO2, relative to arterial blood gas (SaO2), varies by ethnicity.

Methods: In this large retrospective observational cohort study covering four NHS Hospitals serving a large urban population in Birmingham, United Kingdom, consecutive pairs of SpO2 and SaO2 measurements taken on the same patient within an interval of less than 20 min were identified from electronic patient records. Where multiple pairs of measurements were recorded in a spell, only the first was included in the analysis. The differences between SpO2 and SaO2 measurements were compared across groups of self-identified ethnicity. These differences were subsequently adjusted for age, sex, bilirubin, systolic blood pressure, carboxyhaemaglobin saturations and the time interval between SpO2 and SaO2 measurements.

Findings: Paired O2 saturation measurements from 16,818 inpatient spells between 1st January 2017 and 18th February 2021 were analysed. The cohort self-identified as being of White (81.2%), Asian (11.7%), Black (4.0%), or Other (3.2%) ethnicities. Across the cohort, SpO2 was statistically significantly higher than SaO2 ( < 0.0001), with medians of 98% (interquartile range [IQR]: 95-100%) vs. 97% (IQR: 96-99%), and a median difference of 0.5% points (pps; 95% confidence interval [CI]: 0.5-0.6). However, the size of this difference varied considerably with the magnitude of SaO2, with SpO2 overestimating by a median by 3.8pp (IQR: 0.4, 8.8) for SaO2 values <90% but underestimating by a median of 0.4pp (IQR: -2.0, 1.4) for an SaO2 of 95%. The differences between SpO2 and SaO2 were also found to vary by ethnicity, with this difference being 0.8pp (95% CI: 0.6-1.0,  < 0.0001) greater in those of Black vs. White ethnicity. These differences resulted in 8.7% vs. 6.1% of Black vs. White patients who were classified as normoxic on SpO2 actually being hypoxic on the gold standard SaO2 (odds ratio: 1.47, 95% CI: 1.09-1.98,  = 0.012).

Interpretation: Pulse oximetry may overestimate O2 saturation, and this is possibly more pronounced in patients of Black ethnicity. Prospective studies are urgently warranted to assess the impact of ethnicity on the accuracy of pulse oximetry, to ensure care is optimised for all.

Funding: PIONEER, the Health Data Research UK (HDR-UK) Health Data Research Hub in acute care.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9096912PMC
http://dx.doi.org/10.1016/j.eclinm.2022.101428DOI Listing

Publication Analysis

Top Keywords

spo2 sao2
12
retrospective observational
8
observational cohort
8
cohort study
8
oxygen saturation
8
sao2 measurements
8
measurements
6
spo2
6
sao2
5
impact ethnicity
4

Similar Publications

Quantification of Vascular Remodeling and Sinusoidal Capillarization to Assess Liver Fibrosis with Photoacoustic Imaging.

Radiology

January 2025

From the Department of Radiology, The Third Affiliated Hospital of Southern Medical University (Academy of Orthopedics, Guangdong Province), Guangzhou, China (W.L., L.S., R.Z., Y.Z.); and Medical Research Center, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Southern Medical University, Zhongshan 2nd Rd, Yuexiu District, Guangzhou 510000, People's Republic of China (J.L., H.L., X.Z., F.X., T.S., K.L., L.N.).

Background Photoacoustic microscopy (PAM) can be used to detect strong absorption from endogenous and exogenous contrast material, making it promising for detailed structural and functional imaging of hepatic sinusoids, including dynamic visualization of permeability. Purpose To evaluate whether PAM-based quantitative parameters of liver function and integrity (lacunarity, blood oxygen saturation [Sao], and Evans blue [EB] permeability) are associated with histopathologic indexes of fibrosis in a mouse model. Materials and Methods Between October 2022 and July 2023, a total of 35 male C57BL/6 mice were included in this study and received intraperitoneal injection of carbon tetrachloride to establish mouse models of progressive liver fibrosis, with seven mice in each group.

View Article and Find Full Text PDF

Background: Judicious utilisation of tertiary care facilities through appropriate risk stratification assumes priority, in a raging pandemic, of the nature of delta variant-predominated second wave of COVID-19 pandemic in India. Prioritisation of tertiary care, through a scientifically validated risk score, would maximise recovery without compromising individual safety, but importantly without straining the health system.

Methods: De-identified data of COVID-19 confirmed patients admitted to a tertiary care hospital in South India, between April 1, 2021 and July 31, 2021, corresponding to the peak of COVID-19 second wave, were analysed after segregating into 'survivors' or 'non-survivors' to evaluate the risk factors for COVID-19 mortality at admission and formulate a risk score with easily obtainable but clinically relevant parameters for accurate patient triaging.

View Article and Find Full Text PDF

Background: Dental impressions are crucial in pediatric dentistry, but exaggerated gagging can obstruct this process. Various methods have been proposed to manage the gag reflex (GR).

Aim: This study aimed to evaluate and compare the effectiveness of laser acupuncture and electroacupuncture in controlling children's GR.

View Article and Find Full Text PDF

Objective: the study aimed to analyze the therapeutic effects of neuromuscular electrical stimulation (NMES) combined with respiratory muscle training (RMT) on patients with moderate-to-severe chronic obstructive pulmonary disease (COPD).

Methods: 135 patients with moderate/severe chronic obstructive pulmonary disease were selected as the research object and randomly selected. 72 cases were divided into rehabilitation group and 63 cases in control group.

View Article and Find Full Text PDF

Introduction: This study aimed to compare changes in retinal oxygen saturation 1 month after femtosecond-assisted laser in situ keratomileusis (FS-LASIK) in Chinese adults with myopia using retinal oximetry.

Methods: In this prospective, observational, single-center cohort study, Chinese adults aged 18-45 years with myopia were categorized into four groups according to spherical equivalent (SE), with 66 eyes characterized as low myopia (LM -3.00D < SE ≤ -0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!