Purpose: Traditional tension band fixation of patella fracture is associated with high reoperation rates. The purpose of the study was to assess strength of fixation in patella fractures treated with either a non-metallic all suture-based technique or traditional metallic tension band wiring.

Methods: Ten paired human cadaveric specimens were included. A transverse fracture was created, reduced and fixated with a non-metallic or metallic approach. Non-metallic fixation was done according to a previously published technique, metallic fixation was done according to AO description. Specimens were fixed in 90° of flexion and underwent 200 cycles of loading by pulling the Quadriceps tendon to 300 Newton. Fracture displacement was optically monitored. Primary outcome was fracture displacement after 200 cycles compared to the first cycle. Subsequently, load-to-failure was assessed by a monotonic pull to 1000 N.

Results: For cyclic loading analysis, one specimen from each group was excluded due to machine synchronization, resulting in a total population of 18 specimens. Median (min-max) fracture displacement was 0.65 mm (0.06-1.3) in the non-metallic group and 0.68 mm (0-1.23), (p=0.931) in the metallic group. No difference in displacement was found between the two groups in the repeated measures analysis of variance (p=0.5524). For load-to-failure analysis one specimen was excluded due to machine synchronization, resulting a total population of 19 specimens. 2/9 specimens failed in the non-metallic group (at 979 and 635 N) and 2/10 failed in the metallic group (745 and 654 N).

Conclusion: Non-metallic technique is a biomechanically viable alternative to traditional tension band fixation and it can hopefully lead to fewer implant-related complications.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.injury.2022.05.015DOI Listing

Publication Analysis

Top Keywords

tension band
20
band fixation
12
fracture displacement
12
metallic tension
8
patella fractures
8
human cadaveric
8
traditional tension
8
fixation patella
8
200 cycles
8
analysis specimen
8

Similar Publications

Background: Patellar fractures present challenges in treatment, with traditional methods often leading to complications such as loss of reduction and implant failure. This study aimed to compare a novel suture fixation technique with the traditional tension band method using finite element analysis.

Methods: CT images of a healthy 35-year-old male were used to construct 3D patellar models.

View Article and Find Full Text PDF

We studied the correlation between changes in the interscrew angle (screw divergence) and the correction achieved with tension band plates applied for valgus deformities of the knee region. Twenty-eight children with 68 operated physes were included in this retrospective review. The interscrew angle and screw trajectory angle were measured in the initial and follow-up radiographs.

View Article and Find Full Text PDF

This article aims to present a comprehensive technical note detailing our preferred treatment approach for tibial tuberosity avulsion fractures in the adult and elderly populations, particularly in scenarios characterized by low tissue quality and limited bone stock. Existing literature on this fracture type is scarce, with many described techniques relying on optimal bone quality for effective screw fixation of the tibial tuberosity. Various methods for tibial tuberosity avulsion fixation include K-wires, cannulated screws, staples, tension bands, suture anchors, and in select cases, direct transosseous sutures.

View Article and Find Full Text PDF

Case: A 67-year-old woman sustained a periprosthetic tibial tubercle avulsion fracture with extensor mechanism disruption. She underwent open reduction internal fixation (ORIF) with orthogonal mini-fragment plates applied in a tension band fashion with patellar tendon suture augmentation. Radiographs, range of motion, and patient-reported outcomes were completed over 1 year.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to evaluate the biomechanical properties of SutureTape as an alternative technique for arthrodesis of the metacarpophalangeal (MCP) and proximal interphalangeal (PIP) joint arthrodesis when compared with surgical steel wire.

Methods: A total of 32 fingers (index, long, ring, and small) from two matched pair cadaveric hands were used. K-wire and surgical steel wire were used for MCP and PIP joint arthrodesis of the control group (group I), whereas K-wire and SutureTape were used for the experimental group (group II).

View Article and Find Full Text PDF