In this study, a carbon paste filling method was proposed as a simple strategy for fabricating high-density bipolar electrode (BPE) arrays for bipolar electrochemical microscopy (BEM). High spatiotemporal resolution imaging was achieved using the fabricated BPE array. BEM, which is an emerging microscopic system in recent years, achieves label-free and high spatiotemporal resolution imaging of molecular distributions using high-density BPE arrays and electrochemiluminescence (ECL) signals. We devised a simple method to fabricate a BPE array by filling a porous plate with carbon paste and succeeded in fabricating a high-density BPE array (15 μm pitch). After a detailed observation of the surface of the BPE array using a scanning electron microscope, the basic electrochemical and ECL emission characteristics were evaluated using potassium ferricyanide solution as a sample solution. Moreover, inflow imaging of the sample molecules was conducted to evaluate the imaging ability of the prepared BPE array. In addition, Prussian Blue containing carbon ink was applied to the sample solution side of the BPE array to provide catalytic activity to hydrogen peroxide, and the quantification and inflow imaging of hydrogen peroxide by ECL signals was achieved. This simple fabrication method of the BPE array can accelerate the research and development of BEM. Furthermore, hydrogen peroxide imaging by BEM is an important milestone for achieving bioimaging with high spatiotemporal resolution such as biomolecule imaging using enzymes.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/acs.analchem.1c05354 | DOI Listing |
Cryst Growth Des
November 2024
Department of Chemistry, University of Iowa Chemistry Building, Iowa City, Iowa 52242, United States.
Radiation detection (dosimetry) most commonly uses scintillating materials in a wide array of fields, ranging from energy to medicine. Scintillators must be able to not only fluoresce owing to the presence of a suitable chromophore but also withstand damage from radiation over prolonged periods of time. While it is inevitable that radiation will cause damage to the physical and chemical properties of materials, there is limited understanding of features within solid-state scintillators that afford increased structural integrity upon exposure to gamma (γ) radiation.
View Article and Find Full Text PDFChemElectroChem
August 2024
Department of Chemistry, Iowa State University, 1605 Gilman Hall, 2415 Osborn Drive, Ames, IA 50011-1021.
Analysis of single cancer cells is critical to obtain accurate patient diagnosis and prognosis. In this work, we report the selective dielectrophoretic capture and electrochemical analysis of single melanoma cells at an array of interlocked spiral bipolar electrodes (iBPEs). Following dielectrophoretic capture, individual melanoma cells are hydrodynamically transferred into picoliter-scale chambers for subsequent analysis.
View Article and Find Full Text PDFTalanta
October 2024
Graduate School of Environmental Studies, Tohoku University, 6-6-11 Aramaki Aoba, Aoba, Sendai, Miyagi, 980-8579, Japan; Graduate School of Engineering, Tohoku University, 6-6-11 Aramaki Aoba, Aoba, Sendai, Miyagi, 980-8579, Japan. Electronic address:
Bipolar electrochemical microscopy (BEM), which visualizes the concentration distribution of molecular species in biological systems by electrochemiluminescence (ECL), is expected to be applied to the high-spatiotemporal-resolution imaging of biomolecules, enabling the analysis of cellular functions. In the past, the molecular species that could be imaged by BEM were generally restricted to oxidized molecules due to the limitation derived from the ECL mechanism of the luminophore. Recently, the imaging of dopamine (DA), a reduced molecule, was achieved using Ru (bpy)/glutathione disulfide (GSSG) as a cathodic luminophore.
View Article and Find Full Text PDFAnal Chem
July 2024
Jiangsu Engineering Laboratory of Smart Carbon-Rich Materials and Device, State Key Laboratory of Digital Medical Engineering, School of Chemistry and Chemical Engineering, Southeast University, Nanjing 211189, China.
In situ sensitive detection of multiple biomarkers in a single cell was highly necessary for understanding the pathogenesis mechanism and facilitating disease diagnosis. Herein, a bipolar electrode (BPE)-electrochemiluminescence (ECL) imaging chip was designed for ultrasensitive in situ detection of multiple miRNAs in single cells based on a dual-signal amplification strategy. A single cell was trapped and lysed within the microtrap of the cathode chamber and an HCR amplification process and nanoprobes (Fc/DNA/FeO) were introduced, leading to a large number of electroactive molecules (Fc) being modified on the surface.
View Article and Find Full Text PDFAnal Chem
April 2024
School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210023, P. R. China.
A multicolor electrochemiluminescence (ECL) biosensor based on a closed bipolar electrode (BPE) array was proposed for the rapid and intuitive analysis of three prostate cancer staging indicators. First, [Irpic-OMe], [Ir(ppy)(acac)], and [Ru(bpy)] were applied as blue, green, and red ECL emitters, respectively, whose mixed ECL emission colors covered the whole visible region by varying the applied voltages. Afterward, we designed a simple Mg-dependent DNAzyme (MNAzyme)-driven tripedal DNA walker (TD walker) to release three output DNAs.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!